MACT – Subpart ZZZZ (4Z) Reciprocating Internal Combustion Engines (R.I.C.E.) MCIC Workshop

MACT – Subpart ZZZZ (4Z) Reciprocating Internal Combustion Engines (R.I.C.E.) MCIC Workshop. Joe Foutz March 27, 2012 – Hickory, NC Division of Air Quality March 29, 2012 – Raleigh, NC

studs
Télécharger la présentation

MACT – Subpart ZZZZ (4Z) Reciprocating Internal Combustion Engines (R.I.C.E.) MCIC Workshop

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MACT – Subpart ZZZZ (4Z)Reciprocating Internal Combustion Engines (R.I.C.E.)MCIC Workshop Joe Foutz March 27, 2012 – Hickory, NC Division of Air Quality March 29, 2012 – Raleigh, NC Mooresville Regional Office

  2. NC DAQ Interim Policy While investigating the De-Delegation of Subpart 4Z, DAQ has : • Inserted “Place Holder” Language in the Air Permit for Area Sources • NC DAQ continues to incorporate NSPS IIII and JJJJ into Air Permits and ensure facility compliance. • During site visits, NC DAQ Inspectors should be identifying RICE sources • NC DAQ continues to stay up-to-date on EPA activities on Subpart 4Z.

  3. 4Z Study Group Good News: NC DAQ accepted authority to ensure compliance with Subpart 4Z Bad News: NCDAQ accepted authority to ensure compliance with Subpart 4Z

  4. Engine Population

  5. Next Steps • Survey Forms

  6. Next Steps 1) Survey Forms 2) Administrative Permit Amendment for Non-TV • 300 HP < Existing Non-Emergency CI < 500 HP • Existing Non-Emergency CI > 500 HP 3) CI and SI Engines at TV • Informational Letter / DAQ Website 4) Engines with Work Practice Requirements • Area Source : Emergency and CI and SI < 300 HP • Major Source : Emergency and CI and SI < 100 HP

  7. Stack Testing Existing Non-Emergency CI > 300 HP at Area Sources • Submit Protocol • DAQ will be developing a sample • DAQ Observation • Facility Required to Notify DAQ prior to Test • DAQ not required to attend the test • Submit Results

  8. Questions Contact : Joe Foutz 704-235-2225 Joe.Foutz@ncdenr.gov Or Your Regional Office Asheville RO Mooresville RO Raleigh RO 828.296.4500 704.663.1699 919.791.4200 Fayetteville RO Washington RO Wilmington RO 910.433.3300 252.946.6481 910.796.7215 Winston-Salem RO 336.771.5000