1 / 64

ERT 246 HYDROLOGY & WATER RESOURCES ENGINEERING

ERT 246 HYDROLOGY & WATER RESOURCES ENGINEERING. DISCHARGE MEASUREMENT. Study !!!. Ms Siti Kamariah Bt Md Sa’at School of Bioprocess Engineering sitikamariah@unimap.edu.my. DISCHARGE/STREAMFLOW MEASUREMENT TECHNIQUE. Streamflow and Measurement.

tavi
Télécharger la présentation

ERT 246 HYDROLOGY & WATER RESOURCES ENGINEERING

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ERT 246 HYDROLOGY & WATER RESOURCES ENGINEERING DISCHARGE MEASUREMENT Study !!! Ms Siti Kamariah Bt Md Sa’at School of Bioprocess Engineering sitikamariah@unimap.edu.my

  2. DISCHARGE/STREAMFLOW MEASUREMENT TECHNIQUE

  3. Streamflow and Measurement • The character, amount, and timing of discharge from a basin tells a lot about flow paths within the basin. • Stream flow is one of the most important topics in engineering hydrology because it directly relate to water supply, flood control, reservoir design, navigation, irrigation, drainage, water quality, and others.

  4. Need for Stream flow Measurements Floodplain management Flood forecasting & analysis Reservoir operations Low flows – water quality concerns Design structures – culverts, bridges, storm water systems Evaluate changes in land use on watersheds and/or changes in climatic regimes

  5. Floods

  6. Need for Streamflow Measurements • Important to hydrogeologist to identify how to create stream hydrographs from discharge measurements

  7. Measurement of discharge • Method used depends on type of study, size of river and flow, data requirements, etc. • Streamflow measurement techniques can be broadly classified into 2 categories: • Direct determination – area-velocity method, dilution techniques, electromagnetic method, ultrasonic method • Indirect determination – hydraulic structures, slope-area method

  8. Streamflow Measurements • Serves as the basis for many water resources engineering designs • Three approaches • Measurement of water stage (water level) • Measurement of flow velocity • Hydraulic Structure

  9. Con’t

  10. Streamflow Measurements • Measurement of Water Stage • Water stage: the elevation above some arbitrary datum of water surface at a station • Types of Gages Measuring River Stage: • Staff gage – vertical or inclined • Suspended – weight gage • Recording gage (automatic data logger) • Crest – stage gage ( used to indicate high water mark) • Pressure sensor • Float

  11. Figures of Stream Gauges

  12. Stream gauges

  13. Streamflow Measurements • Measurement of Flow Velocity • Current meter • Dilution • Manning Equation • Floats: Suitable for straight channel, V = L/T

  14. Current Meters

  15. Discharge (Q) Measurement

  16. Area-Velocity Method

  17. Measuring Streamflow in small streams with a pygmy current meter

  18. Discharge (Q) Measurement Large rivers – from bridges or boats

  19. Current Meter Method • 3 types of current meter • Propeller type : for high discharge • Price type using anemometer • Electromagnetic type : for low river flow • Rating curve for current meter is given by: • V = a + bN • where V = flow velocity; • a = starting velocity to overcome mechanical friction; • b = equipment calibration constant; • N = revolutions/sec.

  20. For river velocity measurement, we need: • Wading/Paddle • Bridges • Boat • Cablecar • Cableway

  21. Velocity-Area Method • Mostly/frequently used • River cross-section determined • Velocity measured using • Float (for straight channel) • Current meter • Vertical velocity measured at 0.2d and 0.8d if depth,d >0.6m. If d<0.6m, velocity measured at 0.6dm.

  22. Velocity-Area Method • Q = [Velocity x Area] • Need to know width of channel (w), Depth of channel (d), and Velocity of flow (V) (ft/s or m/s) • Area = w x d • Because depth & velocity vary across a channel: • Important to divide the channel into manageable segments (slices); Typically use 10-20 segments • For each segment measure depth, width and velocity

  23. Measuring Streamflow Discharge Procedure: at each segment measure depth then velocity If Depth < 0.6m, take one reading @ 60% depth If Depth > 0.6m take 2 measurements and compute the average One @ 20% depth One @ 80% depth Average the two readings

  24. Measuring Streamflow Discharge • Two method of measurement • Mean section method • Mid section method

  25. Mean section

  26. Mid section

  27. Example Calculation: Find the Q for this case: V = 0.25 N + 0.05 Where V= velocity (m/s) N = number of revolution/s • Using mean-section method • Using mid-section method

  28. Example Calculation:

  29. Mean-section method Q = 9.736 m3/s

  30. Mid-section method Q = 9.986 m3/s

  31. Dilution gauging • Using tracer/chemical at upstream • For uneven stream base, good method for turbulent streams • Q can be determined by tracer quantity and concentration at upstream and downstream (after dilution) using mass transfer equation. • need to use tracer that is a) easily soluble, b) have no or very low natural concentrations in stream, c) be conservative, d) easily detectable at low concentrations, e) ecofriendly, f) affordable

  32. Dilution gauging • Example of tracer: • Chemical: Sodium cloride,sodium dicromat,manganese sulphate • Dye: sodium fluoroscein, Rhodamine-WT • Radioactive: Bromine-82,Sodium-24,Iodine-132 • 2 method • Sudden/Gulp injection • Constant rate injection

  33. C1,q C2(q+Q) Q Dilution gauging: Constant Rate Injection

  34. Example calculation • 20 g/L of tracer injected at upstream of the river at rate 0.01 L/s. Concentration of tracers at downstream is 5 ppb. Estimate the discharge of the river at downstrean. Assume the initial concentration of tracer is very low. Solution: q =0.01 L/s = 10-5 m3/s C1 = 20 g/L = 20 000 g/m3 C2 = 5 ppb = 5 x 10-6 g/L = 5 x 10-3 g/m3 Q = C1/C2 x q = (20 000/5 x 10-3 )x 10-5 = 40 m3/s = 40 000 L/s

  35. Conversion factor • 1 g/L = 10-3 • 1 mg/L = 10-6 = 1 ppm • 1 μg/L = 10-9 =1 x 10-3 g/m3 = 1 ppb

  36. Where: V = volume of tracers (m3) t1=time of tracer induced at upstream(point 1) t2=time of tracer detected at point 2 C1,V1 C2, Q2 Q Dilution gauging: Sudden Injection

  37. Example Calculation: • 100 liter NaCL at concentration 10 g/L induced at river upstream. Average NaCl concentration after an hour at 800 m distance, at downstream are 0.02 mg/L. Estimate the river discharge at downstream. • Solution:

  38. Sonic methods • - Measure speed of small particles in the flow • Can also track and subtract bottom speed

  39. Some gages are designed to measure just high flows

  40. Hydraulic Structures • Used for small watersheds – such as experimental watersheds – where need accurate, continuous flow measurements. • Two types: • Weirs • Flumes

  41. Weirs Obstruct flow and force it through a notch Stage-Q relationship established mathematically for different types of notches

  42. Weirs • Generally used in small streams • Various types • V-notch for accurate low flow • Rectangular • Handles higher flows • Less accurate at low flows • Trapezoidal -- an intermediate weir • Concerns • Sediment & debris are trapped • Leakage

  43. Trapezoidal Weir

  44. Trapezoidal Weir

  45. Rectangular Weir