1 / 4

Temperature & Humidity Monitoring through WiFi

By using a wireless LAN, recorded data will be automatically uploaded to the T&D Web Storage Service.<br>T&D WebStorage Service can be used with mobile devices such as smart phones and tablets, enabling easier<br>access to data anytime, anywhere. This service also enables the monitoring of current readings, graph display,<br>alert monitoring, and downloading of recorded data using the T&D application.<br>

Télécharger la présentation

Temperature & Humidity Monitoring through WiFi

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 16 Jun 2015 Temperature & Humidity Monitoring through WiFi Seamless Access to Recorded Data By using a wireless LAN, recorded data will be automatically uploaded to the T&D Web Storage Service. T&D WebStorage Service can be used with mobile devices such as smart phones and tablets, enabling easier access to data anytime, anywhere. This service also enables the monitoring of current readings, graph display, alert monitoring, and downloading of recorded data using the T&D application. * User registration is required to use the T&D WebStorage Service. For details see the T&D WebStorage Service website. Data Analysis using T&D Graph T&D Graph enables the viewing of recorded data in graph form, no matter whether the data is stored on a local computer or at T&D WebStorage Service. The user can also open data by searching for specific keyword, or merging multiple data files for long-term graph display. The data filtering feature enables the searching and analysis of data by user-defined criteria and the displaying of highest, lowest, and average measurements for a specified time span. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 4 2 66 11 44 l Fax : (+971) 4 2 66 11 55 email: sales.uae@vackerglobal.com Part of VackerGlobal Group Our offices : UAE (Corp. Office), India, Oman , Kuwait, USA www.vackerglobal.com

  2. 16 Jun 2015 Setup and Data Download from Mobile Devices Recording start/stop and the downloading of recorded data for TR-7wf series devices can be carried out directly via iOS and Android mobile devices. This enables easier access to recorded data without having to collect data loggers from their locations. IMPORTANT: * To use these functions, download and install the T&D application "ThermoWEB" on the mobile device(s) you wish to use. * Operation of buttons on the TR-7wf is required during communication, therefore we recommend placing it in a reachable position. USB Communication with PC for Setup and Data Download Just like previous T&D data loggers, TR-7wf series devices can be connected to a PC with a USB communication cable (sold separately). The USB connection allows for direct PC operation, such as device settings, downloading and analysis of recorded data, even when a wireless connection is not available. To make settings from a PC, download and install the T&D software "TR-7wf for Windows" on your PC. For analysis of recorded data, please download the "T&D Graph" software. IMPORTANT: A USB communication cable is not included with the data logger. Please purchase it separately. Battery Operation for up to 1.5 years Battery-powered operation means the device can be placed anywhere without the need for AC power. Depending on the settings, the device can be used continuously for up to one and a half years before its batteries need to be replaced. Logging Capacity of 8,000 Data Sets One data set consists of readings for all channels in that type of unit. At the longest recording interval of 60 minutes, recording can continue consecutively for one year. Wide Selection of Optional Sensors T&D offers a variety of optional sensors for TR-71wf/72wf, including a high precision temperature/humidity sensor supplied with the TR-72wf-H model. Features include the wide range (-60°C to 155°C) measurement of temperature. Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 4 2 66 11 44 l Fax : (+971) 4 2 66 11 55 email: sales.uae@vackerglobal.com Part of VackerGlobal Group Our offices : UAE (Corp. Office), India, Oman , Kuwait, USA www.vackerglobal.com

  3. 16 Jun 2015 TR-72wf TR-72wf-H TR-71wf Temperature 2ch (Internal 1ch / External 2ch) Temperature 1ch, Humidity 1ch (External) Temperature 1ch, Humidity 1ch (External) Measurement Channels Polymer Resistance Platinum Resistance Electrostatic Capacitance Thermistor Thermistor Sensor °C, °F °C, °F %RH °C, °F %RH Measurement Units Internal Sensor -10 to 60 °C (*1) - - - - -40 to 110 °C (Supplied Sensor) -60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type) Measurement Range 10 to 95 %RH External Sensor 0 to 55 °C -30 to 80 °C 0 to 99 %RH ±2.5 %RH [at 25 °C, 10 to 85 %RH] ±4.0 %RH [at 25 °C, 0 to 10 % or 85 to 99 %RH] At temperatures other than 25 °C and ≥ 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower (*2) Avg. ± 0.3 °C [- 20 to 80 °C] Avg. ± 0.5 °C [- 40 to -20 °C / 80 to 110 °C] ±0.3 °C [0 to 50 °C] ±0.5 °C [all other temperatures] ±5 %RH [at 25 °C, 50 %RH] ±0.5 °C Accuracy Measurement Resolution 0.1 °C 0.1 °C 1 %RH 0.1 °C 0.1 %RH Thermal Time Constant: Approx. 75 sec. Response Time (90%): Approx. 190 sec. Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 20 sec. Response Time (90%): Approx. 7 min. Responsiveness Measurements (fixed or alternating display), Battery Warning Mark, etc. LCD Display Items 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Logging Capacity Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Interval Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) Recording Mode Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 4 2 66 11 44 l Fax : (+971) 4 2 66 11 55 email: sales.uae@vackerglobal.com Part of VackerGlobal Group Our offices : UAE (Corp. Office), India, Oman , Kuwait, USA www.vackerglobal.com

  4. 16 Jun 2015 Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs. Auto-upload Interval Wireless LAN Communication • Standard: IEEE 802.11b • Security (*3): WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES) • WPS 2.0 : Push Button Configuration • Protocol: HTTP, DHCP, DNS USB Communication (*4) • USB 2.0 (Mini-B connector) Communication Interfaces AA Alkaline Battery x 2 (AA Ni-MH batteries may also be used), USB Bus Power (5V 200mA) Power With wireless LAN communication: Approx. 10 days to 1.5 years (Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more) Without wireless LAN communication: Approx. 1.5 years Battery Life (*5) H 58 mm x W 78 mm x D 26 mm Dimensions Approx. 100 g (including batteries) Weight Operating EnvironmentTemperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) Temperature Sensor (TR- 0106) x 2 High Precision Temperature/Humidity Sensor (HHA-3151) x 1 Temperature/Humidity Sensor (THA-3001) x 1 Accessories AA Alkaline Battery (LR6) x 2, Registration Code Label, Manual Set (Warranty Included) *1 : When wireless LAN communication is used frequently, the measurement of the internal sensor may rise by around 0.3 °C. *2 : When used in environments where temperature and humidity are over the values of 50 °C 75 %, 60 °C 50 %, 70 °C 35 %, and 80 °C 25 %, sensor hysteresis may fluctuate by values greater than ±1.5 %RH. Under certain circumstances, it may take some time to return to normal measurement capability. *3 : The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security. *4 : Optional USB Mini-B Cable US-15C is required for USB communication. *5 : Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. All the images and data are copyrighted to the manufacturer T&D Corporation Japan Vacker LLC l PO Box 92438 l Dubai l UAE Phone : (+971) 4 2 66 11 44 l Fax : (+971) 4 2 66 11 55 email: sales.uae@vackerglobal.com Part of VackerGlobal Group Our offices : UAE (Corp. Office), India, Oman , Kuwait, USA www.vackerglobal.com

More Related