An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. S53WWJAVORNIK - 144/14

  2. JAVORNIK - 144/14 S53WW Zakaj transverter? • - najhitrejša pot do kvalitetne UKV postaje • - imamo obilico bolj/manj kvalitetnih KV postaj • - na trgu ni kvalitetne UKV postaje • - dokaj nezahtevna gradnja

  3. JAVORNIK - 144/14 S53WW Zakaj v S5 UKV tekmovalci potrebujemo kvalitetno postajo? • večina lokacij (predvsem sosednjih) se medseboj vidi, ker so locirane na gorskih vrhovih • uporaba visokih moči • uporaba večih antenskih sistemov

  4. JAVORNIK - 144/14 S53WW Lokalni oscilator

  5. JAVORNIK - 144/14 S53WW TX konverter

  6. JAVORNIK - 144/14 S53WW RX konverter

  7. JAVORNIK - 144/14 S53WW

  8. JAVORNIK - 144/14 S53WW

  9. JAVORNIK - 144/14 S53WW

  10. JAVORNIK - 144/14 S53WW Kakšen je kvaliteten tekmovalni UKV oddajnik? • čimbolj linearen (IMD39,41, ... > 130 dBC) • lokalni oscilator z nizkim faznim šumom (Pn < 150 dBc/Hz@100 kHz) • nizek širokopasovni šum oddajnika • uporaba kvalitetnih oklopljenih kablov in ohišij

  11. JAVORNIK - 144/14 S53WW TX IMD

  12. JAVORNIK - 144/14 S53WW “Špricanje”, kaj je to?

  13. JAVORNIK - 144/14 S53WW Kaj še? • uporabljajmo dobro prilagojene antene • tranzistorski “linearji” morajo imeti aktivno vezje za prednapetost baze in morajo biti napajani z nominalno napetostjo (13,8 V ni 12 V) • tranzistorskih “linearjev” nikoli ne vzbujamo do več kot 2/3 njihove nominalne izhodne moči • izogibajmo se stikalnim usmernikom • uporaba LCD monitorjev oz. notesnikov

  14. JAVORNIK - 144/14 S53WW Kakšen je kvaliteten tekmovalni UKV sprejemnik? • ravno prav občutljiv (NF = 2,0 dB) • čimbolj linearen (IP3in > 0 dBm) • vzdrži visoke vhodne nivoje (Pin > -20 dBm) • lokalni oscilator z nizkim faznim šumom (Pn < 150 dBc/Hz@100 kHz) • dovolj selektiven (Lstopband > 120 dB)

  15. TA TS JAVORNIK - 144/14 S53WW Zadostna občutljivost na 144 MHz! NF = 2,0 dB (T = 170 K) !!! Šumna temperatura antene na JN75DS (02.07.1999, ob 19:00 LT) 370 K  3,5 dB 800 K  5,8 dB 1200 K  7,1 dB 1600 K  8,1 dB (S/N)APRX/TA (S/N)SPRX/(TS + TA) (S/N) = (S/N)S/(S/N)A = TA/(TS + TA) (S/N) = - 3 dB ; TS= TA (S/N) = - 2 dB ; TS= 0,6TA (S/N) = - 1 dB ; TS= 0,3TA (S/N) = 0 dB ; TS= 0 K

  16. JAVORNIK - 144/14 S53WW Kako določimo ojačenje RX konverterja? G = 25 dB T = 67 K (NF = 0,9 dB) L = 0,5 dB Kabel RXVRT IF RX 5 dB  630 K 12 dB  4300 K 18 dB  18000 K L [dB] G T [K] TIF [K] TS = TL + 10L/10  (T + TIF /G) 170 35+ 75 + TIF /G 60 33 m 7/8” 18 m 1/2” 11 m AircomPlus 11 m H2000 6 m RG-214 TIF = 18000 K  G = 300  25 dB

  17. JAVORNIK - 144/14 S53WW Kakšni so dejanski nivoji motilnih signalov? PRX [dBm] PMDS (@2,4 kHz) = -138 dBm PRX (S9) = -93 dBm PRX (S9 + 60 dB) = -33 dBm (DR = 105 dB) PRX (500 W + 32 dBi, 10 km) = -7 dBm (DR = 131 dB) R [km]

  18. JAVORNIK - 144/14 S53WW Primer razporeditve tekmovalnih lokacij okoli JN75DS? 76JG 76BD 68 km 76CC 66XE 51 km 47 km 38 km 75KX 66WA 51 km 75GV 75EV 24 km 43 km 15 km 65WW 76PB 84 km 43 km 75ES 10 km 75DS 23 km 35 km 75FO 65XM

  19. JAVORNIK - 144/14 S53WW Kaj v resnici oddajamo? TX IMD Fazni šum Širokopasovni šum

  20. JAVORNIK - 144/14 S53WW Kakšen naj bo sprejemnik? • ker je S/N oddajnih signalov samo (!) 100 - 105 dB, ni potrebe, da bi bil sprejemnik boljši! • tako na oddaji kot na sprejemu uporabljamo isti VFO -zanima nas fazni šum oscilatorja na oddaljenostih od 30 kHz naprej, ki mora biti vsaj -105 dBc/2,4 kHz, kar je enako -139 dBc/Hz! • IP3 naj bo tak, da dva signala z nivojem -33 dBm tvorita 105 dB IMD produkta (IP3IN = -33 + 105/2  20 dBm), kar je nemogoče doseči (če naj bo NF = 2 dB)!

  21. JAVORNIK - 144/14 S53WW Kako določimo potrebno linearnost RX konverterja? RXVRT IF RX G IP3in [dBm] IP3out = IP3in + G [dB] IP3in [dBm] P1dB [dBm] IP3  P1dB + 10 dB 1/IP3in= 1/IP3in + G/IP3in IP3in (@50 kHz, @14 MHz, IPO on)  24 dBm (FT-1000mp) Pinmax (@50 kHz, @14 MHz, IPO on)  18 dBm (FT1000mp)

  22. JAVORNIK - 144/14 S53WW Kakšne so zahteve za linearnost posameznih podsklopov?

  23. JAVORNIK - 144/14 S53WW Kako obstoječo gradnjo še izboljšati? • kristalni oscilator nadomestimo z VFOjem ustrezne kvalitete! • na ta način lahko KV postajo uporabljamo samo še kot IF Rx/Tx na fiksni frekvenci (npr. 9 MHz)! • kar pomeni, da lahko med XVRT in IF RIG vgradimo kristalni filter! • na TX bomo na ta način občutno znižali oddajni širokopasovni šum (ostane le še fazni šum VFOja in šum oddajne verige XVRTja (-118 dBc/2,4 kHz z 10 dBm nivojskim TX mešalnikom)! • na RX bomo znižali nivo IMD produktov!

  24. JAVORNIK - 144/14 S53WW Na kakšen način se še da omiliti motnje? • ne uporabljajmo fiksnih antenskih sistemov (razen za tiste smeri, ko ne bomo nikomur na sprejemu močnejši kot -33 dBm = S9 + 60 dB)!!! • tudi sicer bodimo čimbolj agilni pri sukanju anten! • uporabljajmo antene z ozkim sevalnim diagramom! • bodimo čimbolj mobilni po frekvenci! • med dvema CQ-jema naj bo vsaj 5 sekundna pavza!!!