1 / 22

Solar Power Converter

Solar Power Converter. Senior Design Project David Kline, Jet-Sun Lin, Ting-Hau Ho. Goals of the Project. Create an efficient means to collect, convert, and store solar energy in a battery Create a monitoring and switching circuit to control charging/discharging cycles

alia
Télécharger la présentation

Solar Power Converter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Solar Power Converter Senior Design Project David Kline, Jet-Sun Lin, Ting-Hau Ho

  2. Goals of the Project • Create an efficient means to collect, convert, and store solar energy in a battery • Create a monitoring and switching circuit to control charging/discharging cycles • Convert stored energy from battery to a 120V(ac) output

  3. Overview

  4. Stage 1. Solar Panel • Obtained from Prof. Krein • In direct sunlight: • Voc=22.2 V • Isc=300mA • Resulting in power output of 6.66W • Incident power expected=260W (based on 0.2m2 panel and 1300W/m2 solar constant) • Efficiency=2.56%

  5. Stage 2. DC Step-Down • Design Based on MaximMAX724 • PWM Regulated LC circuit • Converts 14.25-24+ V tosteady 13.8V (adjustable via turnpot) up to 5A • Original design based on Maxim MAX830 scrapped due to pinout/size considerations

  6. Stage 2. DC-Step Down • Steady Voltage over entire range of solar panel inputs (14.25-24+ V) • Efficiency: 76%

  7. Stage 3. Monitor & Switch

  8. Stage 3. Monitor & Switch • Relay-based design using Magnecraft W60HE1S-12DC and W60HE2S-12DC • Original voltage monitor design based on Maxim MAX8215 scrapped • Final Voltage Monitoring Circuit based on LM741CN op-amps • Monitoring Circuit is adjustable with turnpot • Precision up to 0.01V

  9. Stage 3. Monitor & Switch • 13V Voltage Monitor switches at Vbatt=12.98V

  10. Stage 3. Monitor & Switch • Voltage monitor A (11 V) (Green LED): • V (battery) >11V: connect DC/AC converter with battery. • V (battery) <11V: disconnect DC/AC converter from battery.

  11. Stage 3. Monitor & Switch • Voltage monitor B (13 V) (Red LED): • V (battery) >13V: disconnect solar converter from battery. • V (battery) <13V: connect solar converter with battery.

  12. Stage 4. Battery • Genesis EP Series G12V26Ah10EP Lead-Acid • Original design based on current monitoring • Voltage across terminals varies during charging cycle • Discharge reversal electro-chemical process

  13. Stage 4. Battery

  14. Stage 5. DC/AC Inverter • PWM Process • Compare 60Hz sine wave to 75kHz triangle wave resulting in PWM signal driving MOSFETs

  15. Stage 5. DC/AC Inverter • ICL8038 generating 60Hz sine wave • Vpp=2.55-3.0V (depending on Vbatt) • DC offset of ½ Vbatt • SG3525 generating 75kHz triangle wave • Vpp=3.0V • DC offset of 1.5V • The two waveforms are required to be on same scale, so a coupling circuit was added

  16. Stage 5. DC/AC Inverter • SG3525 provides 2 outputs to drive the 2 complementary MOSFET pairs • A MIC4424 MOSFET driver amplifies the PWM signal and provides a high-impedance output to the MOSFETs

  17. Stage 5. DC/AC Inverter • Full-Bridge inverter driven by PWM

  18. Stage 5. DC/AC Inverter • Current must flow through load • Current must never be allowed to flow directly through a single leg to ground • Low drain to source resistance of MOSFET causes very high current to flow and damages MOSFET • PWM timing is important to prevent burn-out

  19. Stage 5. DC/AC Inverter • MOSFETs have switching time of 72ns • SG3525 was set to provide “dead time” of 1.2μs • Inverter output stepped up using a 10:117V transformer

  20. Results & Analysis • Able to obtain VOC=110Vac(rms) • With load connected, Vout=0.34Vac(rms) • Transformer is likely becoming saturated and cannot provide the necessary voltage and current

  21. Results & Analysis • 80% Efficiency on DC/AC Inverter for most loads • Overall Efficiency of Converter: 60.8%

  22. Questions?