1 / 54

PXL-500/-510 Tiger Controller II

PXL-500/-510 Tiger Controller II. The PXL-500 Controller. Manages up to 65,535 cardholders Buffers up to 3,640 events Events stored in FIFO ( F irst- I n- F irst- O ut) order. The PXL-500 Controller. Controller addressing via push-button and LEDs NO dip switches to set.

horace
Télécharger la présentation

PXL-500/-510 Tiger Controller II

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PXL-500/-510 Tiger Controller II

  2. The PXL-500 Controller • Manages up to 65,535 cardholders • Buffers up to 3,640 events • Events stored in FIFO (First-In-First-Out) order

  3. The PXL-500 Controller • Controller addressing via push-button and LEDs • NO dip switches to set

  4. The PXL-500 Controller • Auto configuration: • Doors software automatically downloads controller/network information - no manual data entry • Controller network termination

  5. The PXL-500 Controller • Auto configuration: • Controller communication mode (direct connect, modem, Ethernet) • SB-593 Satellite board installation

  6. The PXL-500 Controller • Inputs and Outputs are transient protected • Handles either • 1 or 2 Readers for single door In/Out controlOR • Two doors using optional SB-593 Satellite board

  7. Power Specifications • Power - 12 VDC @ 1 A • Worst case current draw – with all features and options active • Current Draw • 120 mA for the PXL-500 • 150 mA for an SB-593 • 50 mA to 200 mA dependent upon reader type1 • 200 mA for a LAN-500 • Relay Contact Rating - 1A @ 24 VDC 1 – Wiegand readers may draw more current, refer to the reader’s manual for specifics

  8. Wiring Specifications • RS-232 Serial Communication Cable • 3 conductor, shielded, stranded, AWG-2450 feet maximum run length (per RS-232 spec) • RS-485 Controller Network Cable • 1-pair, twisted, shielded, stranded, AWG-2416,000 feet total network run length

  9. Wiring Specifications • Controller Power • 2 conductor, stranded, AWG-18 • 200 feet maximum run length • Earth Ground • Single conductor, AWG-18 (or larger gauge) • Minimize run length for best grounding conditions

  10. Wiring Specifications • Input and Output Lines • 2 conductor, stranded, AWG-22 • 500 feet maximum run length • Readers • 6 conductor, shielded, stranded (for Keri Prox) • 4 to 7 conductor, shielded, stranded (for Wiegand, by reader type) • MS-3000, MS-4000, MS-5000 • 500 feet maximum run length with AWG-24 • MS-7000 • 500 feet maximum run length with AWG-20

  11. Typical Application Diagram

  12. Block Diagram - Communication RS-485 Controller Network RS-232 PC to Master Controller PXL-510 Serial Port PXL-510 Alarm Panel LAN-500 Ethernet

  13. Block Diagram Unit Protection EE Prom Reader Connections

  14. Block Diagram Status LEDs Address LED Battery

  15. Controller Block Diagram Unit Power Inputs and Outputs Selection Switch

  16. PCB Features • Microprocessors • CPU to manage controller general operation • RISC* processor to manage I/O processing • RISC* processor to manage the Reader receivers * (Reduced Instruction Set Computer )

  17. PCB Features • Socketed EE Prom andPIC • Quick, easy firmware updates • Battery • 5-year, Lithium

  18. PCB Features • Quick disconnect terminals for allwiring connections • Unique RS-485 connector • easily distinguish network connectionfrom other connections • Red power connector • easily distinguish power from other connections

  19. Certifications • CE Declaration of Conformity • C-Tick • CSA C22.2 No. 142 • UL 508 Part XVII • FCC

  20. Communications - PC to Master Controller • RS-232 serial port(TB-12) • Controller automatically detects connection type

  21. Communications - PC to Master Controller • Via direct serial connection OR • Via a pair of modems

  22. Communications - PC to Master Controller • Optional, plug-in TCP/IP module (TB-13) • Controller automatically detects TCP/IP connection • Jumpers reconfigure communication

  23. Communications - Inter-Controller Network • RS-485 serial port (TB-1) • Auto-configuration of network termination • Total network length up to 16,000 feet • Network configuration flexibility • “T” and “star” configurations • Single, twisted-pair, shielded cable • Link up to 128 controllers and 256 doors

  24. Communications - Options • PXL-510 – with second serial COM port • Used as the Alarm Panel interface (TB-11), connecting to Caddx NX8E alarm panels

  25. Inputs • Inputs (TB-4) • Door Status • Request to Exit • Global Unlock (1) or • Aux/Secondary RTE (2) • Master controller only • Master or slave controllers

  26. Outputs • Form-C Output Relays (TB-3) • Door Lock • Alarm • In a Form-C relay, the common always creates a complete circuit with either • The normally-open contact OR • The normally-closed contact

  27. Readers • 2 Reader ports per Controller • Controls either 1 or 2 doors • In / Out control of 1 door • 2-door control with optional SB-593 board

  28. Readers - PXL-500P • Exclusively for MS-Series Proximity Readers • MS-3000 • MS-4000 • MS-5000 • MS-7000 A-Reader: Single Door, In Door, or Door 1 (TB-5) B-Reader: Out Door or Door 2 with SB-593 (TB-6)

  29. Readers - PXL-500W • For Wiegand compatible reader technologies • Pyramid Associates Readers (P-300, P-400, P-500, P-600, P-700) • Bar code, mag-stripe, biometric, etc. A-Reader: Single Door, In Door, or Door 1 (TB-5) B-Reader: Out Door or Door 2 with SB-593 (TB-6)

  30. Readers - PXL-500W • Warning LED (LED-10) • Lights when 12 VDC is selected (as shown in picture) • Protects 5 VDC readers from over-voltage condition • Jumper selectable (JP-5) for either 5 or 12 VDC Wiegand readers (5 VDC is the factory setting)

  31. Unit Addressing • LED Display • Address displayed via easy-to-read LEDs • Provides diagnostic information • Displays over or under supply voltage value

  32. Unit Addressing • Selection Button (S1) • Set unit address • no DIP or rocker switches • no PC pre-configuring • Select diagnostic options

  33. Unit Reset • Reset Jumper (JP3) • Clears unit memory and resets unit • Used in conjunction with S1

  34. Master versus Slave Operation • Master Controller • Must be assigned address “01” • Manages communication between host PC and the controller network • Handles presentation card enrollment (using A-Reader), Show Photo, and ID Card features • Slave Controllers • Can be assigned any other unique address from “02” to “128” • Do not have to be addressed in sequential order

  35. Status LEDs • TXD and RXD for RS-232 • LEDs 2 and 3 for primary serial port • LEDs 4 and 5 for optional serial port • LEDs flicker red/green as data is transferred

  36. Status LEDs • Lock Relay • Lights when relay is active • Alarm Relay • Lights when relay is active

  37. Status LEDs • Power • Lights GREEN when power is ON and OK • Lights RED when power is over or under specification • Communications for RS-485 • Flickers red/green as data is transferred

  38. System Protection • The PXL-5xx controller has the following system protection features: • Metal-oxide Varistors • Transorbs • Gas Discharge Tube • Fused over/under voltage detection • Power status LEDs • Socketed RS-485 IC

  39. System Protection • Power Status (Fuse) LED • Warns the installer of unsafe power conditions • Glows RED if power is reversed • Glows GREEN if there is a power line short or an over current draw condition

  40. System Protection • Gas Discharge Tube • Protect the PCB from damage caused by transients and power surges • MOVs • Protect relays from damage caused by transients and power surges

  41. System Protection • Socketed RS-485 communication IC • For quick repair of damage caused by voltage spikes

  42. System Protection • Thermal Fuse opens under unsafe power or current conditions • CAUTION – Do not touch this component, it is very hot during operation

  43. System Protection • Transorbs protect all signal inputs from damage caused by transients and power surges

  44. Environmental Operating Range • Temperature • 0° to 140 °F (-18° to 60° C) • Humidity • 0% to 90% relative humidity, non-condensing

  45. SB-593 Satellite Expansion Board • Jumper selectable for either: • Second door control with 2 programmable outputs and 6 programmable inputs OR • 4 programmable outputs and 8 programmable inputs • Uses Form C relays

  46. SB-593 Satellite Expansion Board • Snaps into place on the PXL-500 controller • align header connectors and plastic mounting pins to corresponding locations on controller and press into place • Installation LEDs • indicates correct board installation

  47. SB-593 Satellite Expansion Board • Controller auto-detects an installed SB-593 • no additional configuration needed • Status LEDs • Indicate relay active/inactive status • Relay Contact Rating • 1A @ 24 VDC

  48. Options - LCD-1 • LCD-1 - plug-in liquid-crystal display for: • Firmware revision • Date and time • Diagnostic information

  49. Options - LAN-50/100/500 • Provides low cost TCP/IP communication using either: • LAN-50/100 external modules • LAN-500 plug-in module • IT experience required for proper configuration of LAN device

  50. Options - Alarm Panel Interface • Fully integrated access and alarm panel control using the secondary serial port on the PXL-510 panel • Interfaces with the Caddx NX-8E alarm panel

More Related