1 / 21

Diagnostics for RAL's H — Ion Beam Front End Test Stand (FETS)

This talk provides an overview of the various types of diagnostics used at the high-power front end of future high-power proton accelerators based on H-. The talk covers both destructive and non-interceptive techniques, including laser-based methods for detecting detached electrons or neutrals. The FETS team at STFC, RAL, ISIS, ASTeC, and Imperial College are working on the development of the front end, including the use of diagnostics such as laser emittance instruments, beam dumps, and ion sources.

ignacioj
Télécharger la présentation

Diagnostics for RAL's H — Ion Beam Front End Test Stand (FETS)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Diagnostics for RAL's H— Ion Beam Front End Test Stand (FETS) Dan Faircloth, Scott Lawrie, David Lee, Simon Jolly, Jürgen Pozimski, Alan Letchford, Christoph Gabor and many more from the FETS team STFC, RAL, Isis, ASTeC, Imperial College Christoph Gabor STFC (ASTeC, RAL) 1st April 2009 Experimental Hall R8

  2. The talk gives an overview which various types of diagnostics are intended to use at the high power front end Future High Power Proton Accelerators base on H- and demand a specific low energy injector providing a fast chopped ion beam. The “bread and butter” diagnostics has to be reliably and is important for commissioning and daily routine operation. Very often destructive methods. For H- non—interceptive techniques are possible by replacing mechanical equipment by a laser to detect detached electrons or neutrals.

  3. The front end FETS means all parts of the accelerator up to 3MeV including MEBT and laser beam diagnostics. Solenoid LEBT (3), pumping tank, beam stop various diagnostics Differential pumping tank including post acceleration, toroide + laser profile measurement (2D) Laser emittance instrument, diagnostics, beam dump H- ion source, 65-70 keV post acceleration, 50-70mA, 2ms, 50Hz (=>10% max) MEBT with chopper, rebuncher and Quads 324 MHz, 3MeV 4 vane RFQ (~4m)

  4. Motivation and necessity of a front end with a fast chopper "Ideal chopping" is an important issue for future projects to avoid long. losses caused by partially chopped beams (activation!). Due to H- in the injector LINAC a significant higher luminosity in the synchrotron is possible (non Liouville stacking). .... has to be demonstrated on highest current level and full duty cycle

  5. Intensity measurements based on FDC and CT (Fast) Current transformer frequency + band width in coexistence with small pulse length droop can be challenging < 70keV Faraday Cup (FDC) with secondary electron suppression (fixed/ movable versions) Dan Faircloth

  6. Transverse emittance instruments typically measure only in one plane, i.e. 2D equivalent to information loss Post processed data Bellows Faraday Cup Slit 2 Slit 1 Beam Feedthroughs

  7. Principle and technical set up of the pepper pot emittance instrument. Copper block Scintillator screen Fast CCD Camera H- Ion Beam H- Beamlets Tungsten screen The linear shift mechanism mounted to the main flange. Adjustable camera mount.

  8. The binding energy of the additional electron of H- is very low and accessible by laser photon energies. Photo—detachment Process Mechanical parts are replaced by laser beam Diagnostics carried out either on detached electrons or neutrals

  9. Transverse beam particle distribution will be determined by the use of a laser wire profile device (tomograpy). Multiple profile measurements under different angles allow investigation of the spatial beam ion density distribution utilizing tomographic methods.

  10. Emittance measurement instrument based on photo detachment The design has to adapted to beam parameters and other technical constraints, thus less flexible than a slit slit scanner. Also higher costs but non destructive and "online measurements" possible.

  11. A "proof of principle" experiment as an example of this technique y Dy x Result of a "proof of principle" Result of a "proof of principle" experiment done in Frankfurt University, IAP

  12. The front end should deliver first beam (running ion source) within the next 4 (four) weeks. Hopefully! More traditional diagnostics will be used for general purpose Photo detachment is THE preferable diagnostic for tool for H- if you simultaneously want to measure non destructive & online gathering with good coverage (resolution) of phase space. current transformer, slit slit emittance scanner, pepperpot, beam profile screens, Faraday cup (fixed/ movable)

  13. y Dy x

  14. The aims of FETS is to demonstrate key technology for HPPA as well build up skills in accelerator technology in UK The Front End Test Stand Collaboration Dan Faircloth Simon Jolly Scott Lawrie David Lee Alan Letchford Jürgen Pozimski Peter Savage Christoph Gabor Mark Whitehead Trevor Woods Mike Perkins John Back Ajit Kurup Ciprian Plostinar Mike Clarke-Gayther Phil Wise Javier Bermejo Julio Lucas Jesus Alonso Rafael Enparantza Companies: Tekniker, Jema, Elyt Diversified Technology Toshiba Further collaboration: CERN IHEP (China) John Adams Institute, (Oxford)

  15. An emittance scanner can be based on various principle, here slit--slit (2D) and pepperpot (4D) are shown. Tungsten mesh Pepperpot head Slit slit emittance scanner Moving rod Vacuum bellows Mounting flange

  16. LEBT and differential pumping tank

  17. Empty slide Extraction geometry Transport through the analyse dipole (cold box) Post acceleration Dan Faircloth

  18. Empty slide Extraction geometry Transport through the analyse dipole (cold box) Post acceleration