1 / 68

ME444 ENGINEERING PIPING SYSTEM DESIGN

ME444 ENGINEERING PIPING SYSTEM DESIGN. CHAPTER 6 : PUMPS. LAST SESSION. PIPING SYSTEM DESIGN PROCEDURE PIPE THICKNESS PIPE SIZING AND SYSTEM PRESSURE DROP. CONTENTS. Fundamental of Pumps Operating Point Pump Selection Pump Installation. 1. Fundamental of Pumps.

jsarmiento
Télécharger la présentation

ME444 ENGINEERING PIPING SYSTEM DESIGN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS

  2. LAST SESSION • PIPING SYSTEM DESIGN PROCEDURE • PIPE THICKNESS • PIPE SIZING AND SYSTEM PRESSURE DROP

  3. CONTENTS • Fundamental of Pumps • Operating Point • Pump Selection • Pump Installation

  4. 1. Fundamental of Pumps When source pressure is not enough to provide desired output, pump is utilized. SOURCE PIPING SYSTEM END USERS

  5. Pump output • Flow rate and Pressure rise. Flow rate

  6. Pump

  7. Pump input and output • Output = Flow rate and Pressure rise. Flow rate Input energy

  8. Specific Speed

  9. Pump performance Dynamic pump Positive displacement pump

  10. Pump performance range

  11. Performance curves = 3.66 (Ns= 10,000) = 0.57 (Ns = 1,550)

  12. Steep vs. flat curves • Flat curve for closed loop system with variable flow rate • Steep curve for high head and constant flow rate

  13. Affinity law Impeller Diameter Impeller Speed

  14. Example of performance curves

  15. Example of performance curves

  16. Speed of induction motor

  17. Standard motor size

  18. Effect of Fluid Viscosity

  19. Net Positive Suction Head

  20. Net Positive Suction Head Required At low pressure, water can become vapor, causing cavitations. Suction pressure must be maintained above NPSHR to avoid cavitation

  21. Net Positive Suction Head Available MUST Maintain NPSHA > NPSHR z Suction lift Vapor pressure Pressure drop in suction piping

  22. Patm vs Elevation

  23. Example 6.1

  24. 2. Operating Point Pump performance curve Operating point System pressure drop curve

  25. Filling a tank from bottom Pump performance curve

  26. Filling a tank from bottom vs. from top Which way fill faster?

  27. Throttling the discharge valve Throttled valve Fully open valve Pump performance curve

  28. Variable speed drive vs. valve throttling Feedback signal Throttled valve Fully open valve Pump performance curve N1 Pump performance curve N2

  29. VSD for pressure control Pressure signal Valve 1 and 2 open All valve open Pressure set point Pump performance curve N1 Pump performance curve N2

  30. Limitation of VSD Feedback signal System curve Cannot reduce speed

  31. Parallel and Serial Connection Do not exceed Maximum Allowable Working Pressure (MAWP)

  32. Response to Parallel Connection

  33. Parallel Connection of Pumps with Different Size

  34. Utilization of Pressure Tank Pressure Switch Pressure Tank Air Water Pressure in tank Pump operate Pump stop time

  35. Example 6.2

  36. Example 6.2

  37. Example 6.2

  38. Example 6.2

  39. Example 6.2

  40. 3. Pump Selection Best Efficiency Energy cost is far beyond the pump cost

  41. Pump Specification

  42. Pump Nameplate

  43. IP RATING The IP Code, International Protection Marking, IEC standard 60529, sometimes interpreted as Ingress Protection

  44. Example 6.3 Select the suitable pump for Example 5.1 200 lpm @ 50.85m.WG.

  45. Example 6.3 (2) Possible selections: NM12 and NM25/20 50.85 m 200 lpm

  46. Example 6.3 (2) Select NM12: Trim Diameter to 198 mm

  47. Example 6.3 (3) Select NM12: Trim Diameter to 198 mm Pump has efficiency of 49.5% Power consumption 3.2 kW Max power consumption 4kW Select Motor size: 5.5kW Note: follow standard motor size

  48. Example 6.3 (4)

  49. Example 6.3 (5) Dimension of NM12

More Related