250 likes | 385 Vues
Team 13—GeoMELT. 03.05.2010. The Team. Outline. Project Overview Background Goals Major Accomplishments Major Design Decisions Design Process Future Work Obstacles Significant Changes Design Norms Decision Validity Acknowledgements Questions. Project Overview.
E N D
Team 13—GeoMELT 03.05.2010
Outline • Project Overview • Background • Goals • Major Accomplishments • Major Design Decisions • Design Process • Future Work • Obstacles • Significant Changes • Design Norms • Decision Validity • Acknowledgements • Questions
Project Overview Michigan receives ≈ 72 inches of snow annually Lake-effect snow can lead to severe storms, but Calvin never cancels class! http://www.duluthstreams.org/understanding/lake_effect.html
Project Overview • Problems with the Burton St. Entrance to Calvin • Intersection is dangerous to plow during the daytime • Safety for Pedestrians and Vehicles • Maybe a snowmelt system would be a good solution • What kind of snowmelt system? • Conventional Snowmelt systems typically near buildings • Conventional systems also rely on fossil fuels. • Why not use Geothermal energy? • Some electric energy is used to move energy from the earth to the desired surface. • This would mean a green solution to the problem with really low operating costs. Let’s check it out!
Project Overview • Primary Goal: To design and give a recommendation for a geothermal snowmelt system at Calvin’s Burton Street Entrance (learn) • Secondary Goal: To design and construct a small model to demonstrate the operation of a geothermal snowmelt system
Major Accomplishments • Soil Boring • 10 feet down • Noticed stratification of soils • Installed Thermocouples • Still gathering temperatures
Major Accomplishments Sample A Sample B • 5 ft down • Clayey Sand • 7.5 ft down • Fine sand w/ some Clay
Major Accomplishments http://www.bing.com/maps • Decisions about site layout • Where to place the field of horizontal pipes? • How much pavement should we melt? • What obstacles do we have to work around? • Large trees? • Pipes? • Fiber Optic Lines?
Major Accomplishments • AutoCAD Drawings of Site Layout • Area of horizontal field • 10,000 ft2 • Area of pavement to melt • 4000 ft2 • Size of pump house is • Approx 15ft x 15 ft
Major Accomplishments • Cost Estimates
Major Design Decisions • Pump house location • Pipe Selection • Pipe spacing: 9” • Pipe diameter: 3/4” • Ground Source Heat Pump definitely needed
Design Process • Why a heat pump is needed • Horizontal advantages • Unbalanced Load • Cost • Loop design and limitations
Future Work • Model preparation and assembly • System specifications (pump models, pipe from supplier, heat exchanger specifics) • Alternative comparison(s)
Obstacles We Overcame • Our Major Accomplishments • EES equations • Battling the elements while taking data
Obstacles Yet to Overcome • Horizontal loop details • Alternative options • Detailed Cost Estimates
Changes in Project Direction • Initial outlook: this could be great possibility • Current outlook: this is outrageous
Design Norms • Stewardship • Save on energy and reduce fossil fuel use • Balance needs and wants with cost and necessity • Caring • Increase safety for pedestrians and vehicles • Transparency • Operational clarity and explanation • Our recommendation: The bare truth
Validation of Decisions • Experienced Engineers • Uponor tables • ASHRAE calculations and examples
Acknowledgements • Trent DeBoer, GMB Engineering • Steve Schultz, GMB Engineering • Charles Huizinga, Calvin College Physical Plant • Marc Huizinga, Calvin College Physical Plant • Professor Nielsen, Team Advisor • Gary Slykhouse, City of GR Engineering Dept. • Bob Bruggink, of Moore & Bruggink
Questions • Now is the time, here is the place. Carpe Diem