1 / 20

GLD-Calorimeter

GLD-Calorimeter. T.Takeshita for GDL-CAL @Snowmass 2005. Concepts: Large Parameters R/D’s out look. GLD. To identify and measure particles in a jet Largest detector for Linear Collider Largest super conducting magnet HCAL inside coil (3.5m radius) Largest TPC (Tracker : 2m radius).

kat
Télécharger la présentation

GLD-Calorimeter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GLD-Calorimeter • T.Takeshita for GDL-CAL • @Snowmass 2005 Concepts: Large Parameters R/D’s out look

  2. GLD • To identify and measure particles in a jet • Largest detector for Linear Collider • Largest super conducting magnet • HCAL inside coil (3.5m radius) • Largest TPC (Tracker : 2m radius)

  3. GLD-Calorimeter • far from IP ~ separate particles in a jet • minimum geometrical overlap • 1 cm granularity : PFA • Large <=> cost = number of channels • flexibility in the component size • reliability in large area • small dead space

  4. GLD-Calorimeterdetector model • Scintillator strip CAL. • flexible in length (WLS Fiber R/O) • effective segmentation 1 x 1 cm • small photon sensor 2 1cm

  5. GLD-Calorimeterglobal design cv

  6. GDL-CALlayers at 90 • ECAL : R = 2.1 ~ 2.3 m (0.2m) : • 6 mm/layer ( 3 + 2 + 1)mm • 33 layers X0=28 • HCAL : R = 2.3 ~ 3.5 m (1.2m) : • 26 mm/layer ( 20 + 5 + 1)mm • 46 layers ~mint=5.5

  7. GLD-CAL layer ECAL HCAL

  8. GLD-CAL layer HCAL cross ECAL cross

  9. absorber active material Layers barrel/ec strip length N. R/O ECAL W 3mm scintillator 2mm 33/ 33 4cm? ~6M ch HCAL Pb 20mm scintillator 5mm 46/ 48 20cm? ~30M ch GLD-CAL parameters

  10. GLD-CAL R/D’s ECAL test with MAPMT

  11. GLD-CAL R/D’s cont’d Integrated lateral shower profile a typical event L1 L2 L3 L4 L5 L6

  12. GLD-photon sensor MPC R/D single photon eq. MPC100 laser beam spot

  13. GLD-CAL R/D’s cont’d Photon sensor R/D MPC of Hamamatsu 100 pixels 1,2,3,4,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,60 pixels GM at each pixel

  14. GLD-CAL R/D’s cont’d Beam Test at Fermilab 2007 to verify this idea and PFA R/D needed R/O electronics MPC

  15. GLD-CAL-collaborators • Kyongpook (D.Kim) : scintillator • JINR (P.Evtoukhovitch): SiPM • Kobe (K.Kawagoe) : MPC • Niigata (H.Miyata) : MPC pixel • Tsukuba (S.H.Kim,H.Matsunaga) : sim. • KEK (A.Miyamoto, K.Fujii) : sim. • Shinshu (T.Takeshita) : BT

  16. GLD-CAL • Open issues for ECAL • strip is sufficient enough for fine segmentation? <> PFA results which optimize the length of a strip • option • real 1cm x 1cm or smaller cell • if the problem is photon finding

  17. GLD-CAL • Open issue for HCAL • again strip length for hadronic interactions ( neutral hadron) • PFA studies • neutron hits >>> delayed hits • electronics timing

  18. GLD-HCAL a pion event digitized hits

  19. GLD-CAL engineering issues • support for HCAL by coil • support for ECAL by HCAL • cabling • installation

  20. summaryGLD-CAL • largest calorimeter • fine segmented & optimized for PFA • scintillator strip based • technique is proved • photon sensor R/D • electronics R/D • detailed design