SlideServe
Menu
Préférences
© SlideServe · v2026

Comparison of CPTA and Hamamatsu SiPMs

kostya avatar
10 diapositives · 256 Views · Sep 12, 2014

2 nd open meeting of Super KEKB Collaboration 19/03/2009 KEK. Comparison of CPTA and Hamamatsu SiPMs. M.Danilov ITEP. We consider two types of SiPMs as photodetectors for the scintillator KLM. CPTA MRS APD 796 40um pixels, 1.28 mm inscribed circle. 556 pixel version of CPTA SiPM.

Comparison of CPTA and Hamamatsu SiPMs - slide 1
01 / 10Comparison of CPTA and Hamamatsu SiPMs
1 / 17

Télécharger la présentation

Comparison of CPTA and Hamamatsu SiPMs
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. 2nd open meeting of Super KEKB Collaboration 19/03/2009 KEK Comparison of CPTA and Hamamatsu SiPMs M.Danilov ITEP

  2. We consider two types of SiPMs as photodetectors for the scintillator KLM CPTA MRS APD 796 40um pixels, 1.28 mm inscribed circle 556 pixel version of CPTA SiPM Hamamatsu MPPC 667 50um pixels, 1.3x1.3 mm^2

  3. MGPD PROPERTIES

  4. PDE spectral dependence at maximum bias voltage (Yu.Musienko)

  5. Irradiation leads to similar dark current increase in MPPC and MRSAPD Individual p.e. peak are smeared after ~10^10 p/cm^2 However MPPC show fast annealing after irradiation with neutrons

  6. Annealing of MRSAPD is slower than of MPPC? More studies required

  7. Summary MRSAPD and MPPC are practically identical in size and in number of pixels MRSAPD has slightly higher PDE MRSAPD has somewhat smaller X-talk and after-pulses MPPC has shorter pulses and no signal tail MPPC has 4 times smaller dark counting rate MPPC has better uniformity of parameters but PDE varies a lot for fixed gain MRSAPD has ~8 times smaller sensitivity to temperature variations MRSAPD has ~3 times smaller sensitivity to voltage variations MRSAPD is slightly cheaper (subject to negotiations) MPPC will have high statistics data on long term stability soon (from T2K) (SiPMs from MEPhI demonstrated excellent long term stability in ILC calorimeter prototype- only 5 dead photo-detectors out of 8000 in 3 years) MRSAPD and MPPC show similar increase of dark current after irradiation but MPPC has faster annealing (to be checked) Both photo-detectors are adequate for the SuperKEKB KLM However there is very little safety margin in radiation hardness