1 / 16

Envisat Validation Workshop Atmospheric Chemistry Validation Team

Envisat Validation Workshop Atmospheric Chemistry Validation Team Ground-Based Measurements and Campaign Database Subgroup Comparisons with GOMOS air-density and Temperature Profiles. Stéphane Marchand, stephane.marchand@aerov.jussieu.fr.

maili
Télécharger la présentation

Envisat Validation Workshop Atmospheric Chemistry Validation Team

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Envisat Validation Workshop Atmospheric Chemistry Validation Team Ground-Based Measurements and Campaign Database Subgroup Comparisons with GOMOS air-density and Temperature Profiles Stéphane Marchand, stephane.marchand@aerov.jussieu.fr Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 1

  2. Validation Team Projects involved : instruments : validate product: • AOID 153 S. Pal Toronto Lidar T (43.66°N, 79.4°W) • AOID 222 K. H. Fricke Esrange Lidar T, HRTP, density (67.9°N, 20.1°E) • AOID 300 D. De Muer Uccle radio-soundings T (50.8°N, 4.35°E) • AOID 360 P. Keckhut OHP Lidar HRTP (43.94°N, 5.71°E) • AOID 9100 F. Congeduti Rome lidar T (41.83°N, 12.65°E) Level 2 GOMOS : GOM_NL__2P* Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 2

  3. Intercomparison of air-density Profile AO 222 2002-08-15 Dist. : 184 km Orb . 2400 star ID : 155 Mv : 2.9 T : 6600 K . Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 3

  4. Intercomparison of air-density Profile AO 153 2002-07-25 Orb . 2091/2092 star ID : 18 Mv : T : 9700 K . Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 3

  5. Intercomparison of air-density Profile AO 153 2002-10-25 Orb . 3407 star ID : 84 Mv : T : 4500 K . Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 3

  6. Temperature Temperature = 2 products • (low resolution) Temperature : contribution of O2 band + rayleigh diffusion + atmospheric model ARLETTY (A. Hauchecorne SA/CNES) • High Resolution Temperature (HRTP) : scintillation obtained with photometers Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 4

  7. Intercomparison of (low resolution) Temperature AO153 2002-07-25 AO153 2002-10-25 Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 5

  8. Intercomparison of (low resolution) Temperature AO 222 2002-08-15 Dist. : 184 km Orb . 2400 star ID : 155 Mv : 2.9 T : 6600 K Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 6

  9. Intercomparison of (low resolution) Temperature Some statistical results AO 222 38 GOM_NL__2P* 18 lidar Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 7

  10. Intercomparison of (low resolution) Temperature AO 300 2002-10-01/2002-11-28 Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 8

  11. Intercomparison of (low resolution) Temperature AO 300 2002-10-01/2002-11-28 Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 9

  12. Intercomparison of (low resolution) Temperature Some statistical results AO 300 10 GOM_NL__2* 9 radio-soundings Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 10

  13. LIDAR RMRRome Tor Vergata Lidar site: 41.83°N, 12.65°E, 150 a.s.l Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 11

  14. Intercomparison of High Resolution Temperature Profile AO 222 4 GOM_NL__2P* star ID : 52 Mv : 2.04 T : 4500 K Star ID : 142 Mv : 2.85 T : 8900 K Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 12

  15. Intercomparison of High Resolution Temperature Profile AO 360 2002-04-25 star ID : 81 Mv : 2.36 T : 28000 K Dist. 300 km Time delay : few hours Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 13

  16. Conclusions • difference of performance between • dark/bright limb conditions • lack of knowledge of the model contribution • in these quantities • difficult to validate the HRTP • (reflection on the spatio-temporal differences) • no bias larger than 10% - good • bias lesser than 1% between 15-35 km • seems to be good but the validation must continue Envisat Validation Workshop, ACVT-GBMCD, GOMOS T 12/12/2002 Page 14