Beam losses on ISIS and induced radioactivity David Findlay Head, Accelerator Division

Beam losses on ISIS and induced radioactivity David Findlay Head, Accelerator Division ISIS Department Rutherford Appleton Laboratory / STFC MICE target review, 18 December 2009. 70 MeV H – linac. 800 MeV proton synchrotron. TS-1.

minna
Télécharger la présentation

Beam losses on ISIS and induced radioactivity David Findlay Head, Accelerator Division

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Beam losses on ISIS and induced radioactivity David Findlay Head, Accelerator Division ISIS Department Rutherford Appleton Laboratory / STFC MICE target review, 18 December 2009

  2. 70 MeV H– linac 800 MeV proton synchrotron TS-1

  3. Synchrotron: 800 MeV proton, 50 Hz 5 µC each acceleration cycle Targets: W (Ta coated) Protons: 2 × ~100 ns pulses, ~300 ns apart Moderators: TS-1: 2 × H2O, 1 × liq. CH4, 1 × liq. H2 TS-2: 1 × liq. H2 / solid CH4, 1 × solid CH4 Instruments: TS-1: 20 TS-2: 7 ~330 permanent staff, ~£35M/year budget ~750 experiments, ~1500 users, ~5000 user-visits per year World-leading

  4. Operating ISIS • Beam losses • Concentrated at one place — on collectors • Imperative to keep beam losses low (~1 W/m) • ISIS: ~1 kW lost, 163 m circumference, ~6 W/m — activity would be worse at higher energies • ISIS only ~0.2 MW, but ×2 beam losses would make life very difficult (3 mSv annual dose limit) • UK legal limit: 20 mSv/year • RAL formal investigation level: 6 mSv/year • ISIS limit: 3 mSv/year

  5. Collector straight MICE target

  6. Superperiods 9, 0 and 1 of the ISIS 800 MeV synchrotron

  7. Long mechanical drives to reduce need to work close to high-radiation locations (e.g. when changing motor drives for beam collectors)

  8. Vertical and horizontal collectors in Straight 1,looking downstream and upstream

  9. BLMs in grey trunking

  10. Straight 1 — too active for routine measurement Typical dose rates round synchrotron — data from 2005 and 2006

  11. ~0 V 1.6 V R8BLM1 (V-ms) 2.8 V 5 V

  12. R8BLM1 Sum BLMs 0 V-ms 1.6 V-ms 1.6 V-ms 20.3 V-ms 2.8 V-ms 30.6 V-ms 5.0 V-ms 57.0 V-ms [Old HEP oscillating target strip-out: highest recorded dose rate 100 mSv/h(10 rem/h)] • Without MICE, sum BLMs = 1.6 V-ms • At 1 target dip per second for R8BLM1 = 5 V-ms • Average sum BLMs = (49 × 1.6 + 57.0) ÷ 50 = 2.7 V-ms • 69% greater — not tolerable

  13. Way(s) forward? • Dean’s bump • Create vertical bump (R0VD1, R5VD1, R7VD1, R9VD1)Ramp up over 8–9 ms, maintain over 9–10 ms 6 mm achieved so far • 10 mm vertical bump at MICE target should be possible with new trim quad. PSUs (higher currents and higher slew rates) • Different target configurations and/or materials • E.g. pion production cf. multiple scattering • Beam dynamics modelling • ?