1 / 6

HV capacitor Testing

HV capacitor Testing. Two tasks Capacitor testing (Duke) Capacitor preparation (Hampton) Capacitors under testing Johanson surface mount 1000pf, rated 2000 V, size 821. Material : X7R Choices are limited due to space Capacitors from four different lots (batches).

rene
Télécharger la présentation

HV capacitor Testing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HV capacitor Testing

  2. Two tasks • Capacitor testing (Duke) • Capacitor preparation (Hampton) • Capacitors under testing • Johanson surface mount • 1000pf, rated 2000 V, size 821. • Material : X7R • Choices are limited due to space • Capacitors from four different lots (batches). • ~Two years ago, the same capacitors (from different lots) were radiation tested at CERN and the results were mixed.

  3. HV testing • HV cycle • Connect 30 capacitors from each batch to HV=2000 V and discharge. • Measure the total capacitance every 50 discharges. • Number of cycles : 2000 • Results • Batch 1 • One capacitor • Surface HV breakdown during 1500-1550 cycles • Inner HV breakdown during 1600-1650 cycles • Batch 2/3/4 : No problem • Conclusion : Pass

  4. Test setup

  5. Plan • Repeat the same test with capacitors from HU (encapsulated and legs are attached) • Long term test • 30 capacitors from each batch connected to HV=2000 V and current is monitored. • Irradiation test – CERN • Requirement : All capacitors from all batches should pass. • Decision by the end of 2002. There should be no problem in getting the capacitors (~6 weeks). • Radiation test on ~100 random samples once the production batch is available • Option in case of failure • Go to lesser capacitance with different material (NPO)

More Related