1 / 17

생체계측 II Report #7 2005200427 송성진

생체계측 II Report #7 2005200427 송성진. Multi physics. ref. <Electric Circuit> V o l t a g e C u r r e n t C h a r g e. <Fluid Mechanics> P r e s s u r e F l o w V o l u m e. ρ is density L is length η is viscosity C is compliance. ρ is resistivity. Catheter Model.

roxy
Télécharger la présentation

생체계측 II Report #7 2005200427 송성진

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 생체계측 II Report #72005200427 송성진 Medical Instrumentation II

  2. Multi physics. ref. <Electric Circuit> V o l t a g e C u r r e n t C h a r g e <Fluid Mechanics> P r e s s u r e F l o w V o l u m e ρ is density L is length η is viscosity C is compliance ρ is resistivity Medical Instrumentation II

  3. Catheter Model. We must measure pressure, Pi ! Diaphragm + Strain gage Pi -> Vi - Cable Blood vessel Po -> Vo Sensor Medical Instrumentation II

  4. Equivalent Circuit Model. 1) 2) Medical Instrumentation II

  5. 3) Second order Ordinary Differential Equation(ODE) 4) Laplace equivalent transform Medical Instrumentation II

  6. Damping Ratio Natural Frequency (or undamped Frequency) Medical Instrumentation II

  7. Frequency transfer function Medical Instrumentation II

  8. Medical Instrumentation II

  9. ІHІ 1/2ζ ∞ → 0 ω Wn We know that Wn is 1/root(LcCd) almost 80Hz ~ 90Hz Medical Instrumentation II

  10. Flat (response) ІHІ 1. If ζ = 0.5 , 1/2ζ = 1 ω Wn Critical damping But, Wn isincreasing, not flat So ІHІ is decreasing Medical Instrumentation II

  11. ІHІ 2. If ζ = 1 , 1 1/2ζ = 0.5 ω Wn Over damped It is that high frequency decreasing Medical Instrumentation II

  12. Іvi(ј ω)І Ex) Wn is going to be more 30Hz so that amplified same magnitude. ω 30Hz If Іvi(ј ω)І Medical Instrumentation II

  13. ІHІ • If ζ = 0.25 , Ex) 1/2ζ = 2 1 ω Wn Under damped Medical Instrumentation II

  14. Phaser transfer graph Wn <H → ∞ ω We must regulate phase & magnitude response appropriate -π/2 -π ζ increasing -> G -> B -> R Medical Instrumentation II

  15. Question) Why change D by jω? 1. D operation GeneralRLCCircuit d/dt Δ= D (operater) Operational transfer function Medical Instrumentation II

  16. 2. Fourier transform Medical Instrumentation II

  17. 0 Medical Instrumentation II

More Related