1 / 32

Optimal Planning for Mesh-Based Power Distribution

Optimal Planning for Mesh-Based Power Distribution. H. Chen, C.-K. Cheng , A. B. Kahng, Makoto Mori * and Q. Wang UCSD CSE Department * Fujitsu Limited

wterrence
Télécharger la présentation

Optimal Planning for Mesh-Based Power Distribution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optimal Planning for Mesh-Based Power Distribution H. Chen, C.-K. Cheng, A. B. Kahng, Makoto Mori * and Q. Wang UCSD CSE Department * Fujitsu Limited Work partially supported by Cadence Design Systems, Inc., the California MICRO program, the MARCO Gigascale Silicon Research Center, NSFMIP-9987678 and the Semiconductor Research Corporation.

  2. Motivation (I) • Voltage drop in the power distribution is critical to chip performance and reliability • Power distribution network in early design stages • nominal wiring pitch and width for each layer need to be locked in • location and logic content of the blocks are unknown • impossible to obtain the pattern of current drawn by sinks • transient analysis is essentially difficult • design decisions are mostly based on DC analysis of uniform mesh structures, with current drains modeled using simple area-based calculations

  3. Motivation (II) • Current method in practice • explore different combinations of wire pitch and width for different layers • select the best combination based on circuit simulations • problem: computationally infeasible to explore all possible configurations; the result is hence a sub-optimal solution • What we need: a new approach to optimize topology for a hierarchical, uniform power distribution

  4. Our Work • Study the worst-case static IR-drop on hierarchical, uniform power meshes using both analytical and empirical methods • Propose a novel and efficient method for optimizing worst-case IR-drop on two-level uniform power distribution meshes • Usage of our results planning of hierarchical power meshes in early design stages

  5. Outline • Problem Formulation • IR-Drop on Single-Level Power Mesh • IR-Drop on Two-Level Power Mesh • Optimal Planning of Two-Level Power Mesh • IR-Drop on Three-Level Power Mesh • Conclusion and On-Going Work

  6. Problem Statement • Given fixed wire pitch and width for the bottom-level mesh • Find the optimal wire pitch and width for each mesh except the bottom-level mesh • Objectives • for a given total routing area, the power mesh achieves the minimum worst-case IR-drop • for a given worst-case IR-drop requirement, the power mesh meets the requirement with minimum total routing area

  7. Model of Power Network • Hierarchy of metal layers • uniform and parallel metal wires at each layer • adjacent metal layers connected at the crossing points • Via resistance: ignored • much smaller than resistance of mesh segments • C4 power pads evenly distributed on the top layer • Uniform current sinks on the crossing points of the bottom layer • before the accurate floorplan, the exact current drain at different locations is unknown

  8. Representative Area • Area surrounded by adjacent power pads • Power mesh • # power pads in state-of-art designs: larger than 100 • infinite resistive grid • constructed by replicating the representative area • Worst-case IR-drop appears near the center of the representative area

  9. Outline • Problem Formulation • IR-Drop on Single-Level Power Mesh • a closed-form approximation for the worst-case IR-drop on a single-level power mesh • IR-Drop on Two-Level Power Mesh • Optimal Planning of Two-Level Power Mesh • IR-Drop on Three-Level Power Mesh • Conclusion and On-Going Work

  10. IR-Drop in Single-Level Power Mesh • IR-drop on a hierarchical power mesh depends largely on the top-level mesh • We analyze worst-case IR-drop on a single-level power mesh • power pads • supply constant current to the mesh • regarded as current sources • ground: at infinity • our method: analyze voltage drops caused by current sources and current sinks separately

  11. IR-Drop by Current Sources • Analysis • IR-drop caused by a single current source • an approximated close-form formula [Atkinson et al. 1999] • integrate IR-drop for all current sources • Result: worst-case IR-drop when only current sources are considered • N: # stripes in the representative area • R: edge resistance • I: total current drain in the representative area • C = -0.1324

  12. IR-Drop by Current Sinks • Analysis • uniform resistive lattice: a discrete approximation to a continuous resistive medium • potential increases with D2 where D = distance from the center, if • a continuous resistive medium • evenly distributed current sinks • impose a form proportional to D2 • Result: worst-case IR-drop when only current sinks are considered

  13. Verification of IR-Drop Formula (I) • Worst-case IR-drop • HSpice simulations • fixedtotal current drain I • fixededge resistance R • #stripes between power pads: N= 4 to 12

  14. Verification of IR-Drop Formula (II) Simulation results for worst-case IR-drop on single-level power meshes, compared to estimated values Accuracy within 1% when N > 4

  15. Outline • Problem Formulation • IR-Drop on Single-Level Power Mesh • IR-Drop on Two-Level Power Mesh • an accurate empirical expression for the worst-case IR-drop on a two-level power mesh • Optimal Planning of Two-Level Power Mesh • IR-Drop on Three-Level Power Mesh • Conclusion and On-Going Work

  16. IR-Drop in Two-Level Power Mesh • Model: two uniform infinite resistive lattices • top-level mesh • connected to power pads • wider metal lines • coarser grid • bottom-level mesh • connected to devices • thinner metal lines • finer grid • Analysis method: consider IR-drop on two meshes separately

  17. IR-Drop in the Coarser Mesh • Assumption: currents flow along an equivalent single-level coarse mesh • most current flows along the coarser mesh • IR-drop in the coarser mesh: • N1: # stripes of the coarser mesh in the representative area • Re : equivalent edge resistance • I: total current drain in the representative area • c : a constant

  18. Verification • HSpice simulations of two-level power meshes • fixed total current drain I • fixed Re • fixed routing resource of two meshes • bottom-level mesh is 10 times finer than the top-level one • # stripes of the coarser mesh N1 = 3 ~ 10 V ~ ln(N1): nice linearity

  19. Equivalent Edge Resistance • Re : slope of the line V ~ ln(N1) • HSpice simulations of two-level power meshes • fixed total current drain I • # stripes of the coarser mesh N1 = 19 • bottom-level mesh: 10 times finer than the top-level one • routing resource of the finer mesh = 1  fixed edge resistance of the finer mesh R • different total routing resource r  different Re • Empirically, Re  R / r

  20. IR-Drop in the Finer Mesh (I) • Assumption: finer mesh within each cell formed by the coarser mesh has equal voltage on the cell boundary • coarser mesh: much smaller edge resistance • HSpice simulations of finer mesh • equal voltage on the boundary • fixed edge resistance of the finer mesh R • fixed current drain of each device i • # stripes within each cell: M = 2 ~ 22

  21. IR-Drop in the Finer Mesh (II) Vfine ~ M2: nice linearity

  22. IR-Drop Formula (I) • IR-drop • C1(r), C2(r) are functions of r • HSpice simulations of two-level meshes • fixed total current drain I • bottom-level mesh: 10 times finer than the top-level one • routing resource of the finer mesh = 1 •  fixed edge resistance of the finer mesh R • fixed total routing resource r = 16 • # stripes of the coarser mesh N1 = 1 ~ 9 • C1, C2 obtained by simulation results for N1 = 7 and 9

  23. IR-Drop Formula (II) Simulation results for worst-case IR-drop on two-level power meshes with fixed total routing area, compared to estimated values Accuracy within 1% when N > 4

  24. Outline • Problem Formulation • IR-Drop on Single-Level Power Mesh • IR-Drop on Two-Level Power Mesh • Optimal Planning of Two-Level Power Mesh • a new approach to optimize the topology of two-level power mesh • IR-Drop on Three-Level Power Mesh • Conclusion and On-Going Work

  25. Optimizing Topology with a Given Total Routing Area • Problem Statement • given fixed total routing area r • find optimal # stripes in the coarser mesh N1 • objective = min worst-case IR-drop • Optimization Method • based on the IR-drop formula • E.g., when r = 16, N1* = 3.9

  26. Optimizing Topology with a Given Worst-Case IR-Drop Requirement • Problem Statement • given worst-case IR-drop requirement • find optimal # stripes in the coarser mesh N1 • objective = min total routing area r • Optimization Method • for each value of r • simulate two-level power meshes for a few values of N1 • calculate the values of C1(r), C2(r) • compute the optimal worst-case IR-drop V*(r) • find minimum total routing area r with V*(r) meets given requirement

  27. Example • Requirement: worst-case IR-drop < 30mV • Compute optimal IR-drop V*(r) for each value of r • Optimal r :between 12 and 13 Optimal N1 :3 or 4

  28. Outline • Problem Formulation • IR-Drop on Single-Level Power Mesh • IR-Drop on Two-Level Power Mesh • Optimal Planning of Two-Level Power Mesh • IR-Drop on Three-Level Power Mesh • a third, middle-level mesh helps to reduce IR-drop by only a relatively small extent (about 5%, according to our experiments) • Conclusion and On-Going Work

  29. Optimal Resource Distribution • Problem • given topology of three-level mesh # stripes of three grids • given total routing area • find optimal resource distribution • Method • a simplified power network wire sizing technique Sequential LP method [Tan et al. DAC99] • for a given width assignment, find the voltage at each node by solving a set of linear equations • fix the node voltages and find the optimal width assignment to maximize current drain at the center • repeat this process iteratively until the solution converges

  30. IR-Drop in Three-Level Power Mesh • Analysis method • fix # stripes in the top- and bottom-level meshes • explore different # stripes for the middle-level mesh • find optimal resource allocation and IR-drop • Top, middle and bottom meshes • # stripes: N1 ,N2 and 120 • wiring resource: r1 , r2 and 1 (1 + r1 + r2 = 10) • Middle-level mesh reduces IR-drop to a relatively small extent (about 5%)

  31. Conclusions • Obtained accurate expression for worst-case IR-drop in two-level uniform meshes • Proposed a new method of optimizing topology of two-level uniform power mesh • used to decide nominal wire width and pitch for power networks in early design stages • Ongoing work: • optimization of non-uniform power meshes • interactions with layout or detailed current analysis

  32. Thank You !

More Related