1 / 5

RHIC Status and Plans

RHIC Status and Plans. RSC Meeting 3/23/12 V. Schoefer. RHIC Status. Good news: We came very quickly to near last year’s peak performace Bad news: Appears to be exactly last year’s performance Golden store 16602: Peak lumi 130 10 30 cm -1 s -1 , 1.5e11/bunch

yonah
Télécharger la présentation

RHIC Status and Plans

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RHIC Status and Plans RSC Meeting 3/23/12 V. Schoefer

  2. RHIC Status • Good news: We came very quickly to near last year’s peak performace • Bad news: Appears to be exactly last year’s performance • Golden store 16602: • Peak lumi 130 1030 cm-1s-1, 1.5e11/bunch • ZDC emittance: 23 pi mm mrad • Lumi Lifetime comparable to Run 12 • Assuming a small increase in intensity at store to 1.65e11 and this is slightly better than peak performance last year (lumi would be ~160 compared with Run11 145 s.u) • Polarization (B, Y) ~ (48%, 44%), averaging all available longitudinal Jet numbers, though not really the same conditions

  3. Polarization • Energy ramp transmission • Snake rotation magnitude scan • Run11 rotation angle scans showed little effect • Have not tried to adjust the magnitude of the rotation (could be off from 180 degrees) • Could also affect store lifetime • Orbit harmonic compensation (APEX)

  4. Polarization • Rotator ramp transmission • (see Elke’s presentation for pC data) • May account for systematic difference between blue and yellow at 255 GeV • Spin manipulation may not be local to the IP • Change both rotators of one color at one IP by a large amount, local pol at the other experiment and pC should see no change in direction (change in magnitude might result from depolarization during current change) • This could also contribute to polarization lifetime

  5. Polarization • Store lifetime • Suggestive indication on one store that when snake angle in yellow drifts, polarization lifetime suffers, can scan store-to-store. Adjusts the spin tune, which may be shifted by another source • Spin tune measurement at store with AC dipole

More Related