1 / 26

Recent Studies on ILC BDS and MERIT

Recent Studies on ILC BDS and MERIT. S. Striganov APD meeting, January 24. Muon background from ILC BDS. Halo interacts with thin primary spoilers and produces electrons and photons Electons and gammas hit thick secondary collimators Electromagnetic shower produce muons – about

zeph-jensen
Télécharger la présentation

Recent Studies on ILC BDS and MERIT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent Studies on ILC BDS and MERIT S. Striganov APD meeting, January 24

  2. Muon background from ILC BDS • Halo interacts with thin primary spoilers and produces electrons and photons • Electons and gammas hit thick secondary collimators • Electromagnetic shower produce muons – about 5 10-5 muon/lost electron • Muon background can be reduced about 2000 by using two magnetized spoilers

  3. New tunnel geometry

  4. Magnetized wall

  5. Concrete wall and doughnuts

  6. October 24, 2006 Summary Table Number of Muons in Detector for Three Shielding Conditions Push-pull IR, 500 GeV CM, BDS 2006c Black numbers – Keller, red numbers - MARS * Collimate 0.1% halo, muons from both beams

  7. Keller v.s. MARS • Halo distribution: MARS and Keller – from STRUCT • Interactions with primary collimator: MARS – internal routine, Keller – TURTLE (electron/positron only, no photon transport) • Interaction with secondary collimator: MARS – internal routine, Keller – approximation of shower • Muon production: MARS and Keller – based on same model • Muon transport: MARS – internal routine, Keller uses MUCARLO – no fluctuation of energy loss, simplified multiple Coulomb scattering

  8. Source • TURTLE does not transport photons – there are no photons (about 60% of total energy) produced on primary collimator in Keller simulations. All photon energy goes to electrons/positrons. • Secondary electrons/positrons and gammas produced in MARS calculations agree well with STRUCT.

  9. Geometry update

  10. Detailed comparizon

  11. Conclusions • Acceptable agreement between Keller and MARS calculations in collimation section • Large differences in bending sections • Zeuthen package based on GEANT3 gave 2-3 times more muons than MUCARLO (TESLA, 1994)

  12. Target for muon collider

  13. MERIT experiment The MERIT experiment, to be run at CERN in 2007, is a proof-of-principle test for a target system that converts a 4-MW proton beam into a high-intensity muon beam for either a neutrino factory complex or a muon collider. The target system is based on a free mercury jet that intercepts an intense proton beam inside a 15-T solenoidal magnetic. The Hg jet delivery system will generate a 1-cm diameter mercury stream with velocities up to 20 m/s.

  14. MERIT geometry in MARS

  15. MERIT geometry in MARS

  16. Simulations tasks • Particle fluxes, energy deposition, absorbed doses and residual activities in experimental hall • Absorbed dose and activation of mercury vapor analyzer • Activation of hydraulic fluid • Activation of mercury vapor filter • Secondary particles production

  17. Radiation levels Absorbed dose in Gy/3 1015 protons 30day/1day residual activity in mSv/h

  18. Radiation levels in detector elements • Absorbed dose in mercury vapor analyzer is 630 Gy (top) and 14 Gy (back). Acceptable level is 50-100 Gy. • Residual dose rate on contact after 5 day of irradiation and 1 hour of cooling: mercury vapor analyzer – 0.17 mSv/hr (top), 0.007 mSv/hr (back), hydraulic fluid – 0.021 mSv/hr, mercury vapor filter -0.18 mSv/hr. Acceptable level is about 1 mSv/hr at FNAL, 0.1(?) mSv/hr at CERN

  19. Detector positions and particle fluxes per pulse (3 1013 protons). neutrons (E>100 keV) charged hadrons (E>200 keV)

  20. Detector positions and particle fluxes per pulse (3 1013 protons). electrons (E>200 keV) gammas (E>200 keV)

  21. Energy spectra ( 0 degree detector). Blue lines – all particles, red lines- particles created in attenuator.

  22. Time distributions in 0 degree detector

  23. Energy spectra ( 6.7 degree detector). Blue lines – all particles, red lines- particles created in attenuator.

  24. Energy spectra ( 11.5 degree detector). Blue lines – all particles, red lines- particles created in attenuator.

  25. Energy spectra ( 45 degree detector). Blue lines – all particles, red lines- particles created in attenuator.

  26. Time distribution in 45 degree detector

More Related