1 / 26

Stability Analysis of 400 Ton Lifting Truss

Outline. Background: Heavy Load Lifting in Power Plant Construction Lifting Truss Buckling Problem Stability Evaluation of the Original Lifting TrussRoot Cause and Proposed SolutionStability Evaluation of the Retrofitted Lifting TrussConclusion. Heavy Lifting in Power Plant Construction. W

Télécharger la présentation

Stability Analysis of 400 Ton Lifting Truss

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Stability Analysis of 400 Ton Lifting Truss Luis M. Moreschi Hongchun Liu Peter J. Carrato Bechtel Power Corp.

    2. Outline Background: Heavy Load Lifting in Power Plant Construction Lifting Truss Buckling Problem Stability Evaluation of the Original Lifting Truss Root Cause and Proposed Solution Stability Evaluation of the Retrofitted Lifting Truss Conclusion

    3. Heavy Lifting in Power Plant Construction Wall panels are assembled at ground to reduce # of components being lifted Heavy wall panel assembly weights up to 400 Tons Strand jacks are provided on the structure Lifting beam / truss is used to spread the load evenly to multiple lifting points An approved Rigging Plan is required for critical heavy lifts

More Related