Status on CMOS sensors

Status on CMOS sensors. Auguste Besson on behalf of IRES/LEPSI: M. Deveaux, A. Gay, G. Gaycken, Y. Gornushkin, D. Grandjean, S. Heini, A. Himmi, Ch. Hu, H. Souffi-Kebbati, I. Valin, M. Winter, G. Claus, C. Colledani, G. Deptuch, W. Dulinski (M6/M8 DAPNIA: Y. Degerli, N. Fourches, P. Lutz).

ash
Télécharger la présentation

Status on CMOS sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status onCMOS sensors Auguste Besson on behalf of IRES/LEPSI: M. Deveaux, A. Gay, G. Gaycken, Y. Gornushkin, D. Grandjean, S. Heini, A. Himmi, Ch. Hu, H. Souffi-Kebbati, I. Valin, M. Winter, G. Claus, C. Colledani, G. Deptuch, W. Dulinski (M6/M8 DAPNIA: Y. Degerli, N. Fourches, P. Lutz) • Develop. of large CMOS sensors (3-T/pixel) • Caracterization of the technology without epitaxy • R&D on fast sensors. • 2004 schedule and summary ECFA-Montpellier

  2. History • MIMOSA 1,2,4,5 tested at CERN-SPS with 120 GeV/c - • M6 tests in progress • M7 available soon • SUCESSOR 2 (SUCIMA PROJECT): beam test in 2003 • 40 m pitch, no epitaxial layer. • 2003: M4, M5, M6 tests, M7 fabricated A. Besson, ECFA-Montpellier

  3. 3-T/pixel large CMOS sensors(M5) • AMS 0.6 m (M1 like) • reticle size 19.4 x 17.4 mm2 • 512 x 512 pixels (/ each of 4 matrices) • 17x17 m pitch • 4 sub-matrices per sensors, read-out in parallel • 6 wafers (6’’) built in 2001 • 3 wafers thinned down to 120m (2 in 2003) • 2002 results: • Yield 20-30 % • det ≳ 99%; sp ~1.7 m; <gain> ~0.2% A. Besson, ECFA-Montpellier

  4. 3-T large sensors: 2003(2) • Beam test at SPS (2003) • 3 sensors • 120 GeV/c - • Performance uniformity tests • between sub-matrices, sensors • diode size comparisons Small diode (3x3 m2) Big diode (5x5 m2) A. Besson, ECFA-Montpellier

  5. 3-T large sensors: results(3) • submatrices have similar properties • ~1 dead column / 512 (i.e. ~0.2% det inefficiency) • single point resolution ≲ 2.5 m (still improvable) • Effect of particle incidence • chip turned w.r.t. beam direction • charge as expected A. Besson, ECFA-Montpellier

  6. 3-T large sensors: M5-B (4) • Mimosa 5-B • 23 wafers produced in oct. 2003 • Slightly improved fabrication process (metalisation) • should reduce dead columns rate. • should improve rate of good chips (yield) • setting up thinning to 15 m (Nov 03) (with a Si wafer on the electronics side for handling) • Application to bio-medical imaging (20-30 keV e-) A. Besson, ECFA-Montpellier

  7. 3-T large sensors: application (5) • STAR: extension of the Vertex Detector (2006) • charm physics  small radius, granular and thin detector • 2 pixel layers  ≳ 1000 cm2R(layer 1) ≳ 2 cm ; R(layer 2) ≲ 4 cm ; • M5 performances are close to the STAR requirements • started a collaboration with LBL (and BNL) • first MIMO⋆1 prototype in summer 2004 (new TSMC 0.25 m tech.) • Requirements • pt~ 3 m • 2.6 kRad/year • 2.1010 neq/cm2/year • read out time 10-20 ms • Power ≲ 100 mW/cm2 • sensor thickness ≳ 50 m • Room temperature • What to improve ? • read out time (~ 24 ms) • sensor thickness (~ 120 m) • electronic noise (room T) • yield (not crucial) A. Besson, ECFA-Montpellier

  8. No epitaxial layer prototypes (M4) • Properties: • AMS 0.35 m witout epitaxial layer. Low doped substrate  increases e • 120 GeV/c - SPS beam tests Eff ≳ 99.5 % resolution sp ~2,5 m (new) • Fabrication processes with epitaxial layer is not mandatory ! A. Besson, ECFA

  9. No epitaxial layer (M4)(2) • Rad. tol. studies: • 200 kRad (x-rays), • 1.4 1011 neq/cm2 • S/N ↘ when T ↗ • If T ≲ 20⁰C  no obvious effects on efficiency and spatial resolution • Radiation effects are negligible at this level (200 kRad ;1.4x1011 n/cm2) A. Besson, ECFA-Montpellier

  10. SB1 Charge (1,9,25 pixels) No epi. : SUCCESSOR 2 • SUCCESSOR 2: (M4 like) • bio-medical imaging, SUCIMA project. • (no epi. layer , AMS 0.35 m) • 40x40 m2pixels • beam tests (oct. 2003) • different sub-structures tested • (3T pixel, Self-Bias pixels with 2 different diode sizes) • eff ≳ 99.9 % • sp ~5-6 m (~2 x M4 with 20 m pitch) • best performances for large diodes SB Noise vs T X resolution vs T S/N vs T ? A. Besson, ECFA-Montpellier

  11. R&D on fast sensors • M1-M5  1M pixels read-out in 1-10 ms • FLC  1st VD layermust be read-out in 25-50 s(beamstrahlung) • potentially tremendous data flow: e.g. 15 bits/pixels, t~25 s  500 Gbits/s/106 pixels ! • main goal: fast signal treatment AND data compression integrated in the sensor • Fast // read out of short columns • Different prototypes with different signal treatment: • M6 (with DAPNIA): tests in 2003, • individual pixels and discri work fine, but large spread of pixel caracteristics (pedestal, noise, gain ?) • M7: available soon, tests in 2003-04 • M8 (with DAPNIA): submitted in Nov., tests in 2004 A. Besson, ECFA-Montpellier

  12. Summary • Large sensors (M5) (1M pixels, AMS 0.6 m ) • ready to be used for a real detector • 2nd fabrication (23 wafers) with a better yield expected • thinning down to 15 min progress • application to extension of STAR Vertex detector in 2006 • No epitaxial layer sensors (M4, SUC 2) • validated for m.i.p. detection (eff ≳ 99.5%, sp ~2,5 m) • fits industrial CMOS fabrication tendancy • Fast response sensors (M6, M7, M8) • studies: fab. techno., charge collection system, signal treatment architecture  read out speed, efficiency, zero sup., power diss. etc. • 2003/2004 schedule • M5-B tests  yield, thinning • M⋆1  available in summer 2004, tests in autumn • fast sensors: 2 prototypes • M7 and M8 tests • charge collection studies  ionising radiation tol. A. Besson, ECFA-Montpellier