TR-60 Hydrologic Design Criteria

TR-60 Hydrologic Design Criteria. NRCS Dam Class. TR-60 Min PS Hydrology. NA for structural spillways. TR-60 Min AS Hydrology. Stability Integrity. TR-60 Auxiliary Spillway Criteria. SDH : 6-hr duration ( Stability ) Determine spillway surface erosion

dusty
Télécharger la présentation

TR-60 Hydrologic Design Criteria

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TR-60 Hydrologic Design Criteria

  2. NRCS Dam Class

  3. TR-60 Min PS Hydrology NA for structural spillways

  4. TR-60 Min AS Hydrology Stability Integrity

  5. TR-60 Auxiliary Spillway Criteria SDH: 6-hr duration (Stability) Determine spillway surface erosion Compare actual (SITES) to allowable stress (AH 667) FBH: 6-hr and 24-hr (Integrity) Use most critical duration Sets minimum dam crest Determine spillway integrity (breach)

  6. PSH DRAWDOWN 10 days

  7. PSH 10-Day Drawdown AS Crest 10-d DD Start elev SDH/FBH Start elev PSH

  8. Drawdown – 15% Test 10-d DD < 15% storage volume between PS crest and AS crest Set PS crest as SDH/FBH start elev If drawdown > 15% storage vol Set drawdown elev as SDH/FBH start elev

  9. Start Elev for SDH/FBH Highest of these elevations: 10-day drawdown from PSH (QRF is a factor) PS crest Total sediment

  10. Baseflow & QRF PDIRECT QDIRECT PSH RO RO from RF QRF QRF BF BF BF SDH&FBH RO RO from RF BF BF BF