1 / 16

Design and Performance Expectation of ALPHA accelerator

Design and Performance Expectation of ALPHA accelerator. S.Y. Lee, IU 2/26/2009. 1. Introduction 2. Possible CIS re-build and parameters 3. Issues in the Design of a small electron Synchrotron. 4. Compact photon source 5. Accelerator parameters and performance expectation.

Télécharger la présentation

Design and Performance Expectation of ALPHA accelerator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design and Performance Expectation of ALPHA accelerator S.Y. Lee, IU 2/26/2009 1. Introduction 2. Possible CIS re-build and parameters 3. Issues in the Design of a small electron Synchrotron. 4. Compact photon source 5. Accelerator parameters and performance expectation

  2. Problems of CRANE Linac in Radiation effect experiments:

  3. Our goal is to design a machine that can provide beam debunching, beam accumulation for radiation effect experiments and generate X-ray photons for future applications for both CRANE NSWC and IU Science Communities.

  4. CIS: Circumference =17.364 m, Inj KE= 7 MeV, extraction: 240 MeV Dipole length = 2 m, 90 degree bend, edge angle = 12 deg. ALPHA: No constraint on circumference (C=20m). Use CIS dipoles & cavity; Need Damping wigglers, chicane, electrostatic kickers & septum

  5. Using a single quadrupole as in the DBA Not a good idea!

  6. Quadrupole does not work • How about Robinson wiggler? – not effective in changing Jx • Gradient Damping wiggler Injection kickers Lambertson septum Chicane for laser-electron interaction Damping wiggler cavity • Maximize straight section so that there are space for future applications • Make it easy to operate • C=20 m, B1/B0=1.9 m-1. (AGS: B1/B0=4.1 m-1 )

  7. Pulse from linac Extracted beam Lambertson septum Kicker 1 Kicker2 Debunch in 1 revolution • Beam in and out in one revolution satisfies the CRANE requirement of steady state experiment. • The accelerator can accumulate 250 nC of charge in 10 or more turns and extracted in one turn for transient mode experiment (15J).

  8. Note that a large compaction factor is necessary for achieving de-bunching for the electron beams in a single path! DBA ε=7.8nm αc=0.15

  9. Effect of the gradient damping wigglers

  10. Dynamic Aperture

  11. Emittance and damping time!

  12. Vacuum Emittances are dominated by pressure in low energy, become natural emittances at high energy.

  13. Touschek lifetime • Toucheck lifetime is sensitive to the parameter: • is the rf bucket height, • is the horizontal momentum spread • can range from 0.001 to 1. • we will need a lifetime of 1h • or more. • It can also be varied by changing the momentum compaction factor

  14. In summary, the ALPHA-project includes: I: Put back CIS with 2 electrostatic kickers and one Lambertson magnet, install a surplus linac to demonstrate the single-turn injection and extraction scheme. II: Refurbish and Install CIS cavity. Construct and install damping wigglers to verify the momentum compaction factor tuning and 10 or more turn accumulation! Commissioning the storage ring. III: Build an injector LINAC for beam injection into the storage ring. In the future, one can Move CRANE Linac to IUCF for high intensity beam commissioning. IV: 90MHz cavity for photon source development, Design of Laser system, Optimization of Laser-beam interaction, photon flux and brilliance. For eCIS design, the technology is well understood! The goal for the CRANE radiation effect experiments can easily be met! For the Compact Photon Source, the technology of 100 MW laser is available!

  15. Accelerator Physics research with the ALPHA storage ring: • Quasi-isochronous accelerator beam dynamics (1st and 2nd order compaction factors) • Touschek Lifetime • Nonlinear beam dynamics • CSR • X-ray: Electron beams in an infinitely long linac (αc=0), encountering infinitely long weak undulators. What will be the electron beam distribution?