1 / 11

Lunar Lander Power Systems

Lunar Lander Power Systems. Adham Fakhry Power Group Lunar Descent Phase. Solar cells for Lunar Lander. Ultraflex Solar cells . Ultra Triple Junction Cells. From Spectrolab Efficiency = 28.3% 330 W/m 2 , 400 $/ Watt (for 2kW – 5Kw range) 2.06 kg/m 2 Mass = 1.362 kg Power = 218 W

Télécharger la présentation

Lunar Lander Power Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lunar Lander Power Systems AdhamFakhry Power Group Lunar Descent Phase [Adham Fakhry] [Power Group]

  2. Solar cells for Lunar Lander Ultraflex Solar cells Ultra Triple Junction Cells From Spectrolab Efficiency = 28.3% 330 W/m2, 400 $/Watt (for 2kW – 5Kw range) 2.06 kg/m2 Mass = 1.362 kg Power = 218 W Area = 0.661 m2 Cost = $87,200 • From Able Engineering • Efficiency = 30% • 1000 $/Watt • 150 W/kg • Mass = 1.57 kg • Power = 236 W • Area = 0.78 m2 • Cost = $235,620 [Adham Fakhry] [Power Group]

  3. Battery for Lunar Lander [Adham Fakhry] [Power Group] • To survive a Lunar night, need 5 W for standby power • 145 W-hr/kg. Need 1680 W-hr to survive 14 days. • Need a 11.5 kg battery to meet this requirement, in order to survive the night. • Desired total mass of battery structure: 20 kg • (Insulation, Support Struts, Battery, Power Management and Distribution System) • Batteries obtained from Yardney – Technical Products.

  4. Backup Slide 1: Solar Array Grid 1.0 m 0.113 m 0.357 m 0.7071 m 0.7071 m [Adham Fakhry] [Power Group]

  5. Backup Slide 2: Power Sys. Prop. [Adham Fakhry] [Power Group]

  6. Backup slide 3: Battery Sizing [Adham Fakhry] [Power Group] • Calculation for battery: • Need 5 W for standby power • Mass Battery = 145 W-hrs/kg • Days of use = 14 days = 336 hrs • Usage = 5 X 336 = 1680 W-hrs • Mass = 1680 / 145 = 11.6 kg • Battery needs power distribution system, for managing power and dropping the voltage for other systems, such as camera, coolers, etc.

  7. Backup slide 4: Solar Array sizing [Adham Fakhry] [Power Group] • Solar array Calculations: • Dimensions of Solar cells: • Area of Lander roof = π(1/2)2 = 0.785 m2 • Solar efficiency = 300 W/m2 • Potential max power = 235.6 W • Cost of Solar Cells: • Cost of cells per watt = 1000 $/W • Cost of Cells = 235,619.45 = $235,600

  8. Backup slide 5: Solar Array sizing 2 [Adham Fakhry] [Power Group] • Solar array Calculations: • Dimensions of Solar cells: • Total area = 0.661 m2 • Weight /area = 2.06 kg/m2 • Total weight = 1.362 kg • Cost of Solar Cells: • Cost of cells per Watt = 400 $/W • Cost of Cells = $ 87,200

  9. Backup slide 6: Cost per block [Adham Fakhry] [Power Group] • Solar array Calculations: • Cost of Solar Cells: • Cost of cells per block: $300 per block • Block sizes range from 26.62 cm2 to 29.85 cm2 • Average number of blocks = 360 • Total cost of solar cells = 70,200

  10. Backup slide 7: Potential Power [Adham Fakhry] [Power Group]

  11. Backup slide 8: References [Adham Fakhry] [Power Group] • References: • http://www.yardney.com/ • http://nmp.jpl.nasa.gov • http://www.aec-able.com/corpinfo/Resources/ultraflex.pdf • http://www.spectrolab.com/