Thermal-Hydraulic Analysis in Support to the Integrated Circulation Experiment ICE

Thermal-Hydraulic Analysis in Support to the Integrated Circulation Experiment ICE. Presented by Vincent Moreau CRS4, Energy & Environment Program. WP 4.5 meeting FZR 22-06-2006. Objectives. support to the experiment Check pre-sizing Propose pre-sizing Help understanding

Télécharger la présentation

Thermal-Hydraulic Analysis in Support to the Integrated Circulation Experiment ICE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thermal-Hydraulic Analysis in Support to the Integrated Circulation ExperimentICE Presentedby Vincent Moreau CRS4, Energy & Environment Program WP 4.5 meeting FZR 22-06-2006

  2. Objectives • support to the experiment • Check pre-sizing • Propose pre-sizing • Help understanding • Get confidence with CFD tool • Show it gives results at least as good as 1D analysis • Find its place between 1D analysis and experiment • Possibility to inquire on details • Allow to explore geometrical assembly not analyzable in 1D

  3. ToolStar-CD software suite ( Version 4, beta)Allowing • Enhanced meshing capability: access to complex 3D geometry • Velocity field: evaluation of corrosion risk • Temperature field: onset of freezing, melting or evaporation • Pressure field: onset of cavitation • Conjugated (between fluid and solid) Heat transfer: Heat removal of electrically heated pin • Multi-stream: Heat Exchanger • Free Surface (with strong limitation): Beam target position • Two-phase flow (idem): Gas-lift pump

  4. Three different simulations • Heat removal of an electrically heated pin bundle • Two-phase flow separation at the gas-lift pump top • Heat Exchanger characterization

  5. Simulation 1:Heat Removal of an electrically heated Pin Bundle • Objective: • Check 1D pre-sizing • Check/Set up CFD tool • Main Features: • Extrusion of a 2D geometry • Temperature field • Heat source • Conjugated Heat Transfer

  6. Simulation 2:Two-phase flow separation at the gas-lift pump top • Objective: • Propose consistent precise geometry • Avoid large gas transfer in the Heat Exchanger • Ensure that “free surface” is not necessary for the Heat Exchanger simulation • Main Features: • Complex Geometry • Two-phase flow • Multiple pressure boundaries

  7. Simulation 3: Heat Exchanger characterization • Objective: • Check 1D pre-sizing • Check consistency of the connector sizing • Avoid large local velocity • Avoid Hot/Cold points • Check that “free surface” is not a necessary tool • Main Features: • Complex Geometry • Conjugated Heat transfer • Multi-stream (14)

  8. Free-Surface in Star-CD V4 • Implementation based on VOF method with “contracting” sharp density interface tracking convective scheme • Force Unsteady Flow simulation • Force Upwind differencing for the convective scheme • Difficult to initialise • Stable for density ratio about 1000 but unstable for density ratio about 10000, typical of Air-LBE at 1Atm => To avoid unless critically necessary, specially for steady flows

  9. Two-phase flows in Star-CD V4 • Eulerian approach: two interconnected continua • Permit Steady State Simulation • Force Upwind differencing for the convective scheme • Difficult to initialise often giving long convergence time • Unstable for large density ratio if the heavy phase volume fraction a goes to zero, unless the light phase viscosity is largely increased, which in turn gives unrealistic profiles • On pressure boundaries, both phases flow must be oriented the same, may be sometimes unphysical (low velocity gas exit). • Avoid unless critically necessary, Carefully avoid that a goes to 0 somewhere

  10. Physical Properties Thermo-physical Properties of LBE in function of temperature [°C]. Thermo-physical Properties of Steel in function of temperature [°C].

  11. Simulation 1:Heat Removal of an electrically heated Pin Bundle • Geometry Main Features: • Extrusion of a 2D geometry • Hexagonal Geometry => only 1/12th of domain to simulate • Heat source as heat flux at the boundary • Conjugate Heat Transfer on only one pin to check equivalence of wall temperature representation • No heat transfer through (lacking) solid parts (conservative shortcut)

  12. Mesh and Flow features Domain: 1m high, radius about 4 cm, pin diameter 8.2 mm PbBi inlet on bottom: upward velocity 2. m/s, temperature 300 C, Reynolds  40000. Turbulence intensity 5% and length scale 0.1 mm. PbBi outlet on top. Two lateral symmetry planes. Fixed temperature 300 C with resistance 10-3 m2 K/W on the external wall. Fixed heat flux such as to get 106W/m2 on the active pin walls for a total of 800/12 kW. Adiabatic on the inactive half-pin wall. Numerical schemes and turbulent models: StarCD MARS TVD scheme and k-e model RNG variant. Stationary Calculation, SIMPLE algorithm. Table : main characteristics on the pin mesh

  13. Simulation 1: main results • Bundle correctly sized • Star-CD and Fluent give very similar results • Maximum temperature and velocity under control

  14. Velocity field Uniform inlet velocity main not be really consistent with the experiment

  15. Simulation 2:Two-phase flow separation at the gas-lift pump top Objective: • Propose consistent precise geometry • Avoid large gas transfer in the Heat Exchanger • Ensure that “free surface” is not necessary for the Heat Exchanger simulation Main Features: • Complex Geometry • Rather small bounding dimensions • Two-phase flow • Multiple pressure boundaries Shortcuts: • Gas phase incompressible • Gas density 10kg/m3

  16. Simulation 2: Proposed Geometry • Relatively large connector (10 cm Diameter) • Small penetration of the connector inside the expansion tube • Large penetration of the riser in the expansion tube • Slanted cut to allow expansion and hide connector

  17. Simulation 2: Mesh • Initial objective was to have the gas phase completely separated on the top • Small penetration of the connector inside the expansion tube • Large penetration of the riser in the expansion tube • Slanted cut to allow expansion and hide connector • Numerical outlets, large pressure outlets being unstable • Unstructured base and extrusion • Mesh: 286 000 Cells

  18. Simulation 2: Results Gas Volume Fraction, Bubble Diameter 1mm Gas Volume Fraction, Bubble Diameter 3mm

  19. Simulation 2: Results LBE Velocity, Bubble Diameter 3mm Gas Velocity, Bubble Diameter 3mm

  20. Simulation 3: Heat Exchanger characterization • Objective: • Check 1D pre-sizing • Check consistency of the connector sizing • Avoid large local velocity • Avoid Hot/Cold points • Check that “free surface” is not a necessary tool • Main Features: • Complex Geometry • Conjugated Heat transfer • Multiple pressure boundaries • Multi-Stream (14) • Shortcuts : • Single phase flow • Half domain (for now) • No free surface • k(T91) fixed at 28.5

  21. Simulation 3: Mesh (1/3) • No penetration of the connector inside the Hex • 14 Stream (1 LBE, 13 Water) • Unstructured base and extrusion • Unstructured connector “stuck” to the extrusion mesh • Mesh: 1.15E6 Cells: LBE: 5.4E5, Steel: 2.5E5 (3 rows),Water: 3.6E5

  22. Simulation 3: Mesh (2/3)

  23. Simulation 3: Mesh (3/3)

  24. Simulation 3: Mesh (4/4)

  25. Simulation3: Main results • Simulation converges fast with UD, but keep high mass residual with MARS: to be investigated (buoyancy ?) • Heat Exchanged: • Global 4.5E5 W (Half Domain) • Single pipe Minimum: 3.20E4 W • Single Pipe Maximum: 3.73E4 W • Maximum velocity: 1.4 m/s, pipe in front of the connector • Pressure variation on surface: 1500 Pa (~1.5 cm) • Maximum velocity close to the surface: 0.47 m/s • Minimum LBE Temperature (Wall): 198 C • Maximum Water Temperature (Wall): 265 C (Boiling at 188 C)

  26. Simulation3: Temperature fields

  27. Simulation3: Velocity field

  28. Conclusion • 1D pre-sizing has been globally confirmed • Proposed riser design avoid almost all gas transfer in the Hex. • High Water wall temperature may need a larger connector or partial boiling must be taken into account. • Reason of high residual with MARS scheme (Hex simulation) must be found and possibly put under control.

  29. Perspectives • Give a definitive Riser-connector design • Full (360 degrees) Hex simulation • Test also AISI 316L • Possibility to tune each water channel flow independently for incidental test