1 / 23

Non-linear correction circuits

Non-linear correction circuits. Massimo Giovannozzi Acknowledgements: F. Zimmermann (who prepared the procedure A.4: 450 GeV optics: beta beating, dispersion, coupling, non-linear field quality, aperture) :. Families of non-linear corrector circuits.

thorson
Télécharger la présentation

Non-linear correction circuits

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Non-linear correction circuits Massimo Giovannozzi Acknowledgements: F. Zimmermann (who prepared the procedure A.4: 450 GeV optics: beta beating, dispersion, coupling, non-linear field quality, aperture) : M. Giovannozzi – Extended LTC

  2. Families of non-linear corrector circuits • spool pieces: at dipole ends for b3, b4 and b5; powered differently per arc and per beam; total number of circuits 48 • lattice correctors: in the SSS for a3, b3, and b4; total number of circuits 112 • correction coils for triplet field errors: a3, b3, a4, b4, and b6; total number 40 In total, 200 independent correction circuits. M. Giovannozzi – Extended LTC

  3. Circuits composition M. Giovannozzi – Extended LTC

  4. Target and tolerances for observables These tolerances are reported in LHCPR 501 (by S. Fartoukh and O. Brüning). M. Giovannozzi – Extended LTC

  5. Tolerances on spool pieces settings - I • Spool pieces are meant as local correctors of MBs field quality. • Tolerances on spool pieces settings analysed by M. Hayes (LHC PR 522 and 590). • 1 sigma reduction in DA corresponds to about 20%-40% mis-powering of ALL spool pieces. M. Giovannozzi – Extended LTC

  6. Tolerances on spool pieces settings - II • In case of mis-powering of one single circuits the tolerances are looser. • Global or local correction with non-linear circuits can be envisaged. • Spool pieces are meant as local correctors of MBs field quality. • Tolerances on spool pieces settings analysed by M. Hayes (LHC PR 522 and 590). • 1 sigma reduction in DA corresponds to about 20%-40% mis-powering of spool pieces. M. Giovannozzi – Extended LTC

  7. General measurement scheme • An off-centre orbit through a non-linear element generates a change of phase advance/tune given by • The off-centre orbit can be generated by: • Closed orbit bumps • Dispersion (by energy variation) • Tune measurement allows minimising the tune shift by using the non-linear correctors. • NB: in simulations the non-linear correctors are set according to differences between the approaches are of the order of 10%. M. Giovannozzi – Extended LTC

  8. Expected dipole field quality at injection • In particular: • a3 component well-within tolerances, very likely correction is not required.

  9. Procedures for setting non-linear correctors - I Prepared by F. Zimmermann with the help of S. Readelli Phases for full commissioning Stage A (pilot physics run) M. Giovannozzi – Extended LTC

  10. Procedures for setting non-linear correctors - II

  11. Setting the b3 spool pieces - I Local correction (arc by arc) to within ~ 50% Proposed procedure (F. Zimmermann): • Pre-set spool pieces to values determined with FiDel (magnet measurements and model) • Adjust Q’ to ~2 units with the two families of lattice sextupoles • Check local correction with local dispersion bumps or groups of 7p bumps across individual arcs, octant by octant • Complementarily or additionally, measure off-momentum (chromatic) phase advance M. Giovannozzi – Extended LTC

  12. Setting the b3 spool pieces - II Scheme by M. Hayes (LHC PR 522), O. Bruning (LHC PR 473) (Qx-Qy)+3 mm - (Qx-Qy)-3 mm vs. quality of correction Orbit with 7p bump across one arc; peak value of 3 mm Expected DQ~0.01 for 20% mis-powering of b3 spool pieces. Adjustment of b3 to within 10% is a reasonable target. M. Giovannozzi – Extended LTC

  13. Setting the b3 spool pieces - III Simulated Df for dp/p=10-3 and dp/p=0 (machine as-built). Sector 7-8 features the smallest value of b3 at injection -> small effect 80% powering induces a variation on chromaticity of more than 2 units: Qx: 2 -> -0.7; Qy: 2-> 4.4 M. Giovannozzi – Extended LTC

  14. Setting the b3 spool pieces - IV One missing circuit can be easily detected. M. Giovannozzi – Extended LTC

  15. Setting the skew sextupole a3 - I Some facts: And: Tolerance on this effect: Considering the measured field quality, the tolerances are largely met (the MSS where considered not necessary since Day 1 according to the analysis presented at Chamonix XV)! where M. Giovannozzi – Extended LTC

  16. Setting the skew sextupole a3 - II • Proposed procedure (global approach): • check with off-momentum closest tune approach • Tolerance to meet: M. Giovannozzi – Extended LTC

  17. Setting the b4 spool pieces - I • Global correction to within ~ 30% • Proposed procedure (F. Zimmermann): • Leave lattice octupoles switched off • Separate tunes (to reduce contribution from a3, if needed) • Pre-set spool pieces to values determined with FiDel (magnet measurements and model) • Measure Q’’ vs. b4 and set b4 by minimising Q’’ • Verify detuning with amplitude • Considering the measured field quality, the tolerances are met (the MCO where considered not necessary since Day 1 according to the analysis presented at Chamonix XV)! M. Giovannozzi – Extended LTC

  18. Setting the b5 spool pieces - I • Local correction (arc by arc) to within ~ 50% • Proposed procedure (F. Zimmermann): • First minimize Q’’’ (global) • Measure off-momentum detuning with amplitude; without any correction expect DQ~10-3 at 3s and d=10-3 (8x smaller for single arc) • Complementarily, measure chromatic phase advance (effect could be difficult to detect) • Measure resonant driving terms (option) • Varying kicks to obtain “frequency map’’ (option) M. Giovannozzi – Extended LTC

  19. Setting the b5 spool pieces - II [F. Zimmermann, Chamonix03] Huge global effect of b5. simulated Df for 1s kick for dp/p=10-3 and dp/p=0; 3 cases: (1) no spool piece mis-powered, (2) sextupole circuit KCS45 missing (BPMs 194 to 257), (3) decapole circuit KCD45 missing we can detect missing b3 circuits, but not missing b5! M. Giovannozzi – Extended LTC

  20. Setting the b4(f, d) correctors - I • The Landau octupoles will be used only with higher intensities or with special configurations (TOTEM beam with 156 might be unstable). • The polarity should be checked arc by arc for each family. • Proposed procedure: • Switch on a single family • Set it to about 10%-20% of its nominal strength • Measure Q’’ (it depends linearly on b4, hence the sign is visible) M. Giovannozzi – Extended LTC

  21. Setting the b4(f, d) correctors - II M. Giovannozzi – Extended LTC

  22. Non-linear correctors in low-beta triplets • The non-linear correctors will not be needed until b* < 1 m (from numerical simulations). Hence, they will not be needed for the Phase A. • Procedure to set them to be specified. • A good candidate is the use of IR bumps as it was done in RHIC (J.-P. Koutchouk et al. PAC01, inspired by LEP coupling measurements – 1990.) M. Giovannozzi – Extended LTC

  23. Conclusions • Spool pieces: • Procedure defined: • b3: correction (local) required and feasible • b4: correction (global) probably not required • b5: correction (global) required. Local difficult… • MSS: • Procedure defined, but correction not needed • MO: • Polarity measurement defined: easy to do. • Low-beta triplet correctors: • Correction not needed for Phase A. Strategy known (IR bumps): to be studied in our case Next step: possible implementation in the on-line model? M. Giovannozzi – Extended LTC