1 / 13

45° Tandem Parallel Plate Analyser

SIMION Project. 45° Tandem Parallel Plate Analyser. Louise Belshaw Spiros Divanis Patrik Gunacker Peter Herczku. SIMION Project: Tandem PPA Analyser. PPA ONE. IONS, ELECTRONS. IONS. ELECTRONS. PPA TWO. SIMION Project: Tandem PPA Analyser. `. Tandem Parallel Plate Analyser:

astrid
Télécharger la présentation

45° Tandem Parallel Plate Analyser

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIMION Project 45° Tandem Parallel Plate Analyser Louise Belshaw SpirosDivanis PatrikGunacker Peter Herczku

  2. SIMION Project: Tandem PPA Analyser PPA ONE IONS, ELECTRONS IONS ELECTRONS PPA TWO

  3. SIMION Project: Tandem PPA Analyser ` • Tandem Parallel Plate Analyser: • Build a simple tandem PPA, consisting of two PPAs placed at 90°. • Investigate required voltages and angles of acceptance. • Add an Einzel lens before the input slit of PPA1, and place another between the exit of PPA1 and the entrance of PPA2. • How does this change our results?

  4. SIMION Project: Tandem PPA Analyser SIMION Project: Tandem PPA Analyser ` Simple Tandem PPa PPA ONE SIMION results For this PPA, f = 0.6 Electrons of KE = 1000 eV Expect required V = -600 V Used: -597 V Required Deflecting voltage: Acceptance Solid Angle: α = ± 3° β = ± 5° Ω = 4αβ= 0.018steradians Transmission: Strong angular dependence: With α = 3, β = 5, T = 0.2 % α = 1, β = 1, T = 3 % PPA TWO

  5. SIMION Project: Tandem PPA Analyser SIMION Project: Tandem PPA Analyser Simple Tandem PPa Typical Particle Definitions:

  6. SIMION Project: Tandem PPA Analyser Tandem Ppa Without focussing

  7. SIMION Project: Tandem PPA Analyser ` Tandem PpaWiTh Einzel lens EINZEL LENS 1 EINZEL LENS 2

  8. SIMION Project: Tandem PPA Analyser ` Tandem Ppa With Einzel lens

  9. SIMION Project: Tandem PPA Analyser SIMION Project: Tandem PPA Analyser Tandem Ppa With Einzel lens Voltages: Transmission: With α = 3, β = 5, T = 5 % α = 1, β = 1, T = 30 %

  10. SIMION Project: Tandem PPA Analyser ` Tandem Ppa With Deceleration and focussing

  11. SIMION Project: Tandem PPA Analyser ` Tandem Ppa With Deceleration and focussing Voltages: Transmission: With α = 3, β = 5, T = 0.4 % α = 1, β = 1, T = 9.2 %

  12. SIMION Project: Tandem PPA Analyser Transmission comparison

  13. Thank you for your attention!

More Related