1 / 4

Competence and Service in Molecular Biology

Real Time/Quantitative PCR. Competence and Service in Molecular Biology. Real Time/Quantitative PCR.

happy
Télécharger la présentation

Competence and Service in Molecular Biology

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Real Time/Quantitative PCR Competence and Service in Molecular Biology

  2. Real Time/Quantitative PCR metabion offers Black Hole series of dark quenchers (BHQTM) which were designed for use in real-time PCR assays. These molecules function as efficient quenchers of fluorescence over the entire visible spectrum and into the IR, re-emitting their energy as heat rather than light. Probes made with BHQ quenchers exhibit extremely low background noise and allow for lower copy sensitivity. BHQ-1 has its max absorption at 534 nm and quenches most efficently in the 480 to 580 nm range. BHQ-2 has its λmaxat 579 nm, which enables it to “absorb” fluorescence in the 550 to 650 range. BHQ-3 has its max absorption at 672 nm with an optimal quenching range of 620-730 nm. Competence and Service in Molecular Biology

  3. Real Time/Quantitative PCR BHQ Dye Absorption Maxima and Quenching Range Quencher Abs(nm)Quenching Range (nm) BHQ-1 534 480-580 BHQ-2 579 550-650 BHQ-3 672 620-730 BHQ Dye / Reporter Combinations Quencher Suggested Fluorophores BHQ-1 FAM, TET, JOE, HEX, … BHQ-2 TAMRA, ROX, CY3, LCRed 640, … BHQ-3 CY5.5, IRDye700, LCRed 705, … The unique characteristics of the BHQ classof quenchers permits flexibility in the choice of spectrally well-resolved fluorophores enabling single-tube multiplexing with little or no cross-talk Competence and Service in Molecular Biology

  4. Real Time/Quantitative PCR Absorption spectra of DABCYL-T9 and BHQ-1-T9with the emission spectra of FAM, TET, and JOE. DABCYL andBHQ-1 dye were normalized at the poly-T-absorbance (i.e. 260nm) to better demonstrate the larger extinction coefficient ofthe BHQ-1 dye. RFU=relative fluorescence units. Competence and Service in Molecular Biology