1 / 30

Product Presentation 2008

Product Presentation 2008. Why Specify Actuators? Serious problems of the past. Actuators too often were treated like a commodity item with low first cost the #1 selection criteria Noise. Early Failure. Operational Problems. Recall.

kisha
Télécharger la présentation

Product Presentation 2008

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Product Presentation 2008 F&S Actuator Presentation

  2. Why Specify Actuators? Serious problems of the past. Actuators too often were treated like a commodity item with low first cost the #1 selection criteria Noise. Early Failure. Operational Problems. Recall. The actuator is an Integral part of the Fire Smoke System. F&S Actuator Presentation

  3. Basic Features F&S Actuator Presentation

  4. FSLF 80% of applications 4-6 sq.ft. 350F 15 sec F&S Actuator Presentation

  5. FSNF Introduced 2002 Largest damper is a double section of 16.5 sq.ft at 250F Typically 12 sq.ft. 70 in-# minimum .23A draw at 120V 15 seconds F&S Actuator Presentation

  6. 133 in-lb at 250F <75 sec drive, <20 sec spring UL 11VA Run 6VA Hold Has manual override. Only 24VDC model made – battery and shipboard applications. FSAF F&S Actuator Presentation

  7. Part Numbers Fire Smoke L = 30 in-lb N = 70 in-lb A = 133 in-lb 4 sq.ft 12 sq.ft. 12-18 sq.ft. Failsafe = spring 24, 120, 230 = Voltage F&S Actuator Presentation

  8. -S models F&S Actuator Presentation

  9. FSLF = SPST fixed FSAF (2-position) =SPST 10 degree fixed and a 25-85 degree adjustable switch. F&S Actuator Presentation

  10. FSNF = SPDT fixed FSAF24-SR, -BAL SPDT switches 10 degree fixed and a 25-85 degree adjustable switch. F&S Actuator Presentation

  11. Why specify Belimo? F&S Actuator Presentation

  12. Quality: F&S Actuator Presentation

  13. Micro Controller • Actuator cannot burn out if stalled before full rotation is achieved. • Motor runs cool for a long life span. • DC Motor: No noise when holding. • Very low Current Draw • The BEST - Not the cheapest way to control. 5-year Belimo Warranty F&S Actuator Presentation

  14. Quality: Steel cold-weld clamp. Steel housing. F&S Actuator Presentation

  15. Low Power Draw • FSLF • A 20 amp breaker implies 20 x • 75% / .15 = 100 actuators. • FSNF • A 20 amp breaker can take 20 x • 75% / .23 = 60 actuators. • Company X • 1.25 amp draw gives 15/1.25 = 12. • This is a significant wiring expense on larger projects. F&S Actuator Presentation

  16. GO GREEN WITH ORANGE F&S Actuator Presentation

  17. Belimo Quality ISO 9001 Quality Control FSLF is UL60730-1 which is going to replace UL873 F&S Actuator Presentation

  18. Belimo Quality ISO Certified .1% failure rate over 2 years The only World Class actuators in the HVAC market. F&S Actuator Presentation

  19. Belimo Quality 5-year Belimo Warranty The warranty is on the actuator; if it breaks, we will cover it to the owner or contractor regardless of damper OEM. Our cost to the manufacturers is within a few dollars of the competition. Price should not be the first issue. F&S Actuator Presentation

  20. Recap FSLF 4 sq.ft. 350F 15 sec FSNF 12 sq.ft. 350F 15 sec FSAF 16 sq.ft. 250F 75/20 sec F&S Actuator Presentation

  21. New Products FSAF24-SR Proportional 3-Position FSAF24-BAL F&S Actuator Presentation

  22. FSAF24-SR Proportional F&S Actuator Presentation

  23. F&S Actuator Presentation

  24. FSAF24-BAL Shaft requires a fire & smoke damper and a balancing damper. The FSAF24-BAL allows cost and space savings. F&S Actuator Presentation

  25. FSAF24-BAL F&S Actuator Presentation

  26. FSAF24-BAL Fire Fighters Smoke Control System F&S Actuator Presentation

  27. FSAF24-BAL F&S Actuator Presentation

  28. Smoke Damper Actuators www.belimo.com F&S Actuator Presentation

  29. Competitive Replacement Actuators Training informationInstallation Instructions F&S Actuator Presentation

  30. Thank you AMERICAS F&S Actuator Presentation

More Related