1 / 15

Piping and Instrumentation Diagrams ( P&IDs)

Piping and Instrumentation Diagrams ( P&IDs). Piping and Instrumentation Diagrams ( P&IDs). Pas à l’examen. Ne pas confondre PID et P&ID. Introduction aux P&IDs : http://www.cpdee.ufmg.br/~seixas/PaginaII/Download/DownloadFiles/P&IDs.PDF. Cascade Control. Cascade Control.

locke
Télécharger la présentation

Piping and Instrumentation Diagrams ( P&IDs)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Piping and Instrumentation Diagrams (P&IDs) GEL-2005

  2. Piping and Instrumentation Diagrams (P&IDs) • Pas à l’examen. • Ne pas confondre PID et P&ID. • Introduction aux P&IDs: • http://www.cpdee.ufmg.br/~seixas/PaginaII/Download/DownloadFiles/P&IDs.PDF GEL-2005

  3. Cascade Control GEL-2005

  4. Cascade Control • Single feedback loop: • Cascade loops: • Better rejection of dyi when Gpo(s) is slower than Gpi(s). • yi must be measured. GEL-2005

  5. Cascade Control • Most common cascade control: inner-loop = flow control. • Tuning: • Gci(s): based on Yi(s)/U(s) = Gpi(s) • Gco(s): based on Y(s)/Ri(s) GEL-2005

  6. Single Feedback Control GEL-2005

  7. Cascade Control GEL-2005

  8. Cascade Control GEL-2005

  9. Cascade Control Without Cascade 10% Pressure Drop GEL-2005

  10. Cascade Control With Cascade GEL-2005

  11. Cascade Control With Cascade GEL-2005

  12. Exemple • Voir le fichiercascade.mdl. GEL-2005

  13. Implantation numérique GEL-2005

  14. Implantation numérique Pas à l’examen. e y r + u GP GC - • Connaissant GC(s), on désire une équation récurrente du régulateur pour l’implanter sur un calculateur numérique: • u(k) = a1u(k-1) + a2u(k-2) + … + b0e(k) + b1e(k-1) + … • où u(k) = valeur de u à l’instant présent k • u(k-1) = valeur de u à l’instant d’échantillonnage précédent etc. • Cette équation est calculée à chaque période d’échantillonnage Te. • Choix de Te: temps de réponse (et non constante de temps) de la boucle fermée (Y/R) / a, avec 10 < a < 25 • Étapes: GC(s)  GC(z) a1, a2, …, b0, b1, … GEL-2005

  15. Implantation numérique GEL-2005

More Related