1 / 72

Solutions for Odor & Corrosion Control

Solutions for Odor & Corrosion Control . Providing solutions not just products . Local representative since 1996 www.GoTDM.com 800.300.2844 . Turnkey System integrator and distributor – proving regional field service and installation .

ahava
Télécharger la présentation

Solutions for Odor & Corrosion Control

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Solutions for Odor & Corrosion Control Providing solutions not just products Local representative since 1996 www.GoTDM.com 800.300.2844 Turnkey System integrator and distributor – proving regional field service and installation

  2. New company – cooperative venture including TDM and Gasho Associates More capabilities including field service of equipment Developing new technology for dry media System Integrator

  3. Contacts TDM:George Federico Technical Assistance – proposals, etc Gasho Associates – Shaun Kelley local sales Rep –

  4. Why work with us ?? • Offering multiple technologies • Biofilters • Carbon/media system • Chemical scrubbers • Thermal oxidizers • Odor prevention • Offering the best technologies • OdorToolBiofilters • Theia Air Carbon & Dry media • Altech Scrubbers • Colt Technolgies - Oxidizers • Venturi Aerators • Weatherford H2S Scavenger www.GoTDM.com

  5. Why work with us ?? We provide solutions we work with you to find the best solution for you and your client – we do not force fit what we sell to the project Knowledge and experience We know the technologies and are experts in treating air and odor Scope of supply to fit the project every project has different requirements. We can provide turnkey systems and even install them or just components - your call www.GoTDM.com

  6. Why work with us ?? The TDM/Theia Air difference We work with you when you are designing your system, installing your system and for years afterwards – all systems and equipment can have problems – we will be there for you if ours does We will be there for our customers – even when it is not our equipment www.GoTDM.com

  7. Why work with us ?? The TDM/Theia Air difference We provide a total approach to odor control. This means everything from collection to dispersion www.GoTDM.com

  8. What is an odor exactly Odor is a sensory reaction to one or more aromatic gases. Like noise, it is a perceived offense. Like Noise, this somewhat nebulous term CAN be scientifically defined

  9. Defining odors We define one OU ( odor unit) as the point at which the “average person” begins to detect an odor

  10. “Sewage Odors” Removing some of the compounds will reduce the odor but may not eliminate the problem We must reduce all of the odorous compounds to be successful

  11. What is Odor Control Exactly ?? Simply put, we are trying to prevent odorous compounds from reaching sensory perceptors ( people) Before we design the treatment equipment, we should define what is required to meet this goal

  12. Neighbor Lift Station Dispersion Modeling

  13. Biofiltration Basics In general, contaminated air passes through a fixed bed of media - Media has a thin film of water on the outside - Contaminant gases are solubilized into this film of water where they can be digested by the microbes

  14. Simple Schematic of conventional system 1st & 2nd Generation

  15. Just because something looks good on paper does not mean it will work in the field

  16. Media Makes a Difference ! • Syntheticmedia is now widely used – media does not break down • The media will last but the performance is still not there Second Generation Better but not good enough

  17. Second Generation • Random Packed Media: • Void volume only 35% (Less Effective EBRT) • poor water distribution poor air flow • No means for control of biomass • Higher Pressure Drop, increases over time • Un-Predictable performance • Media is typically treated with chemicals, food, etc

  18. Void or pore volume is all that really matters – and they fall short Effective bed volume

  19. Water build up and dry spots render another portion as useless Dry = no bacteria and no solubilization Water and biomass buildup block the air sending it elsewhere

  20. So what is the actual effective EBCT ????

  21. Third Generation More advanced (Structured) Media Dual Zone Bed; Zone A provides an optimal area for a robust colony of bacteria to reside while Zone B is the “transfer zone” . Void Volume >95% (Effectively increases EBRT) Complete treatment, due to uniform distribution of air Low pressure drop, will not increase over time Maintains its structure over life ensuring predictable performance

  22. Structured Packing

  23. Structured Packing Bacteria Growth Vessel Size Water Layer Air flow

  24. Structured Packing 95 % Void Volume Vessel Size Water Layer Air flow

  25. 100% media utilization no Water Buildup No dry spots Vessel Size Water Layer Air flow

  26. Most Systems are overly complicated • larger media beds – big footprint, very heavy • Typically very expensive • Humidification systems – complicated – require a lot of maintenance • Multiple spray nozzles

  27. Pretty Simple One spray nozzle = even distribution of water No recirculation of water No humidification system

  28. Simple Rule, Simple System Control the water –► control the air, control the bugs

  29. Most biofilters fail due to poor control of the water – uneven water = uneven air = poor treatment = poor biomass By controlling the flow of water through the system we control the air flow keeping it evenly distributed

  30. What does the air flow pattern look like here ?

  31. Structured Packing Bacteria Growth Water Layer Air flow

  32. Taking it one step further • Biomass control. • Getting a strong healthy bacteria colony to grow is important but is only part of the battle • Keeping this biomass from fouling or otherwise interfering with the equipment is just as critical

  33. Biomass Engineering • Multiple contaminants require multiple bacterial colonies • This requires multiple strata to develop which strongly favors a taller media bed • We do not recirculate the water which allows this stratification to take hold

  34. Odortoolbiofiltersare compact, require little or no maintenance and use little water and no chemicals These systems offer high removal efficiencies and very low operating costs Permanent media means no replacement concerns

  35. Most Installations Worldwide 100% success rate

  36. Dry media Systems Taking on your toughest applications without all the mess and expense of wet scrubbers. New media that can take on the highest levels of H2S & mercaptans without a big footprint and without changing the media out frequently

  37. Thermal Oxidizers

  38. Oxidizers Thermal Oxidizers are effective on sludge applications RTO’s ( Regenerative Thermal Oxidizers) are the best approach – lowest maintenance and lowest operating costs They are slightly more expensive than RCO’s ( Recuperative thermal oxidizers) – usually 5-15%

  39. we offer skid mounted and field erected RTO’s ( Regenerative Thermal Oxidizers to treat any size air stream – we also offer RCO’s • Biosolids, Sludge, drying, etc is our specialty • We offer upgrades and retrofits to existing units to reduce your operating costs • 27 years of experience • Full field capabilities • Safe, reliable design

  40. Which one is right for me? • For sludge drying and other low VOC applications, RTO’s are the best choice. • RTO’s use a lot less fuel • RTO’s require a lot less maintenance • RCO’s typically require a rebuild after 5-7 years due to the heat exchangers rusting out

  41. Structured media Our design allows for removal of heat recovery media from the chambers quickly and easily Media can be cleaned and put back in all in one day This will be required once every 2-3 years

More Related