1 / 50

Design of Open Channels and Culverts CE453 Lecture 26

Design of Open Channels and Culverts CE453 Lecture 26.

Télécharger la présentation

Design of Open Channels and Culverts CE453 Lecture 26

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of Open Channels and CulvertsCE453 Lecture 26 Ref: Chapter 17 of your text and HYDRAULIC DESIGN OF HIGHWAY CULVERTS, Hydraulic Design Series Number 5, Federal Highway Administration, Publication No. FHWA-NHI-01-020, September 2001; available at http://www.cflhd.gov/design/hyd/hds5_03r.pdf, accessed March 18, 2006

  2. Design of Open Channels

  3. Longitudinal Slopes • Gradient longitudinal direction of highway to facilitate movement of water along roadway

  4. Drains • Along ROW • Collect surface water A Typical intercepting drain placed in the impervious zone http://www.big-o.com/constr/hel-cor.htm

  5. Drainage Channels (Ditches) • Design • Adequate capacity • Minimize hazard to traffic • Hydraulic efficiency • Ease of maintenance • Desirable design (for safety): flat slopes, broad bottom, and liberal rounding

  6. Ditch Shape • Trapezoidal – generally preferred considering hydraulics, maintenance, and safety • V-shaped – less desirable from safety point of view and maintenance Source: Fabriform1.com

  7. Terms • Steady Flow: rate of discharge does not vary with time (Manning’s applies) • Uniform: channel properties are constant along length of channel • Slope • Roughness • Cross-section • Water surface is parallel to slope of channel • Non-uniform: properties vary

  8. Terms • Unsteady flow: rate of discharge varies with time • Critical depth • a hydraulic control in design • depth of water where flow changes from tranquil to rapid/shooting • Critical velocity: velocity corresponding to critical depth • Critical slope: slope corresponding to critical depth

  9. Flow Velocity • Depends on lining type • Should be high enough to prevent deposit of transported material (sedimentation) • For most linings, problem if S < 1% • Should be low enough to prevent erosion (scour) • For most types of linings, problem if S > 5%

  10. Use spillway or chute if Δelev is large

  11. Rip Rap for drainage over high slope

  12. Riprap (TN Design Manual)

  13. Side Ditch/Open Channel Design-Basics • Find expected Q at point of interest (see previous lecture) • Select a cross section for the slope, and any erosion control needed • Manning’s formula used for design • Assume steady flow in a uniform channel

  14. Manning’s Formula V = R2/3*S1/2(metric) V = 1.486 R2/3*S1/2 n n where: V = mean velocity (m/sec or ft/sec) R = hydraulic radius (m, ft) = area of the cross section of flow (m2, ft2) divided by wetted perimeter (m,f) S = slope of channel n = Manning’s roughness coefficient

  15. Side Ditch/Open Channel Design-Basics Q = VA Q = discharge (ft3/sec, m3/sec) A = area of flow cross section (ft2, m2) FHWA has developed charts to solve Manning’s equation for different cross sections

  16. Open Channel Example • Runoff = 340 ft3/sec (Q) • Slope = 1% • Manning’s # = 0.015 • Determine necessary cross-section to handle estimated runoff • Use rectangular channel 6-feet wide

  17. Open Channel Example Q = 1.486 R2/3*S1/2 n • Hydraulic radius, R = a/P • a = area, P = wetted perimeter P

  18. Open Channel Example • Flow depth = d • Area = 6 feet x d • Wetted perimeter = 6 + 2d Flow depth (d) 6 feet

  19. Example (continued) Q = 1.486 a R2/3*S1/2 n 340 ft3/sec = 1.486 (6d) (6d)2/3 (0.01)1/2 (6 + 2d) 0.015 d  4 feet Channel area needs to be at least 4’ x 6’

  20. Example (continued) Find flow velocities. V = 1.486 R2/3*S1/2 n with R = a/P = 6 ft x 4 ft = 1.714 2(4ft) + 6ft so, V = 1.486(1.714)2/3 (0.01)1/2 = 14.2 ft/sec 0.015 If you already know Q, simpler just to do V=Q/A = 340/24 = 14.2)

  21. Example (continued) Find critical velocities. From chart along critical curve, vc 13 ft/sec Critical slope = 0.007 Find critical depth: yc = (q2/g)1/3 g = 32.2 ft/sec2 q = flow per foot of width = 340 ft3/sec /6 feet = 56.67ft2/sec yc = (56.672/32.2)1/3 = 4.64 feet > depth of 4’

  22. Check lining for max depth of flow …

  23. Rounded

  24. A cut slope with ditch

  25. A fill slope

  26. Inlet or drain marker

  27. Ditch treatment near a bridge US 30 – should pier be protected?

  28. A fill slope

  29. Hidden Drain Where’s the water going to end up?

  30. Median drain

  31. Design of Culverts Source: Michigan Design Manual

  32. Culvert Design - Basics • Top of culvert not used as pavement surface (unlike bridge), usually less than 20 foot span • > 20 feet use a bridge • Three locations • Bottom of Depression (no watercourse) • Natural stream intersection with roadway (Majority) • Locations where side ditch surface drainage must cross roadway

  33. Hydrologic and Economic Considerations • Alignment and grade of culvert (wrt roadway) are important • Similar to open channel • Design flow rate based on storm with acceptable return period (frequency)

  34. Culvert Design Steps • Obtain site data and roadway cross section at culvert crossing location (with approximation of stream elevation) – best is natural stream location and slope (may be expensive though) • Establish inlet/outlet elevations, length, and slope of culvert

  35. Sometimes … you want a dam … why?

  36. Culvert Design Steps • Determine allowable headwater depth (and probable tailwater depth) during design flood – control on design size – f(topography and nearby land use) • Select type and size of culvert • Examine need for energy dissipaters

  37. Headwater Depth • Constriction due to culvert creates increase in depth of water just upstream • Allowable/desirable level of headwater upstream usually controls culvert size and inlet geometry • Allowable headwater depth depends on topography and land use in immediate vicinity

  38. Inlet control • Flow is controlled by headwater depth and inlet geometry • Usually occurs when slope of culvert is steep and outlet is not submerged • Supercritical, high v, low d • Most typical • Following methods ignore velocity head

  39. Example: Design ElevHW = 230.5 (max) Stream bed at inlet = 224.0 Drop = 6.5’ Peak Flow = 250cfs 5x5 box HW/D = 1.41 HW = 1.41x5 = 7.1’ Need 7.1’, have 6.5’ Drop box 0.6’ below stream @223.4’ - OK

  40. Outlet control • When flow is governed by combination of headwater depth, entrance geometry, tailwater elevation, and slope, roughness, and length of culvert • Subcritical flow • Frequently occur on flat slopes • Concept is to find the required HW depth to sustain Q flow • Tail water depth often not known (need a model), so may not be able to estimate for outlet control conditions

  41. Example: Design ElevHW = 230.5 Flow = 250cfs 5x5 box (D=5) Stream at invert = 224 200’ culvert Outlet invert = 224-0.02x200 = 220.0’ (note: = 223.4-.017x200) Given tail water depth = 6.5’ Check critical depth, dc = 4.3’ from fig. 17.23 Depth to hydraulic grade line = (dc+D)/2 = 4.7 < 6.5, use 6.5’

  42. Example (cont.) Design ElevHW = 230.5 Flow = 250cfs 5x5 box Outlet invert = 220.0’ Depth to hydraulic grade line = 6.5’ Head drop = 3.3’ (from chart) 220.0+6.5+3.3 = 229.8’<230.5 OK