This document outlines the findings from the NA62 Straw Working Group meeting held on October 18, 2010. It covers coating adherence tests conducted at FEP, including cross-cut tests on various substrates such as Melinex 406 and Hostaphan RNK 2600. The results demonstrate adherence issues and aging effects on coatings. Permeation tests for gases like Ar and CO2 and surface analysis via XPS provide insights into the properties of the coatings used. Ongoing experiments aim to further understand these materials and enhance performance.

Collaboration of TE-VSC-SCC with NA62 Straw Material Working Group: Coating and Surface Analysis - slide 1
01 / 10Collaboration of TE-VSC-SCC with NA62 Straw Material Working Group: Coating and Surface Analysis
1 / 17

Télécharger la présentation

Collaboration of TE-VSC-SCC with NA62 Straw Material Working Group: Coating and Surface Analysis
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. Collaboration of TE-VSC-SCC with straw-material working group NA62 • Coating adherence tests • Permeation results • Surface analysis results Wil Vollenberg and Delphine Letant-Delrieux TE-VSC-SCC NA62 straw working group meeting; 18-10-2010 W.V. & D.L.D.

  2. SAMPLES FROM: Pilot coating run by FEP: • - Melinex 406; Cu50/AU20: CO2010-07-07A-01 • - Melinex 406; Cu100/AU20: CO2010-07-07A-02 • Hostaphan RNK 2600; Cu50/AU20: CO2010-07-08A-01 • Hostaphan RNK 2600; Cu100/AU20: CO2010-07-08A-02 Coating adherence test at FEP by cross cut test: Cross cut: 11*11 cuts Calibrated scotch on it Pull Percentage of squares that peels off. NA62 straw working group meeting; W.V. & D.L.D.

  3. Adherence tests at CERN:cross test and scotch test Hostaphan RNK 2600 50 Cu + 20 Au 100 Cu + 20 Au NA62 straw working group meeting; W.V. & D.L.D.

  4. Adherence tests at CERN:cross test and scotch test MELINEX 406 100 Cu + 20 Au 50 Cu + 20 Au NA62 straw working group meeting; W.V. & D.L.D.

  5. Items not yet understood: Adherence problems at PEF for Melinex 50 + 20, at CERN Melinex 100 + 20. AT CERN: Aging of samples: Melinex 100 + 20: better adherence after aging ?? Tests of aging in controlled conditions: 100 Cu + 20 Au 50 Cu + 20 Au NA62 straw working group meeting; W.V. & D.L.D.

  6. Adherence tests at CERN:scotch test Hostaphan RNK 2600 50 Cu + 20 Au Melinex 406 50 Cu + 20 Au NA62 straw working group meeting; W.V. & D.L.D.

  7. Items not yet understood: Good adherence for Coatings on Hostaphan RNK 2600, independent of thickness / aging conditions Some unexpected results for adherence of coatings on Melinex 406. NA62 straw working group meeting; W.V. & D.L.D.

  8. Permeation results NA62 straw working group meeting; W.V. & D.L.D.

  9. Uncoated samples coming from rolls coated by Fraunhofer (CA1509465) Surface analysis results (XPS) NA62 straw working group meeting; W.V. & D.L.D.

  10. Future activities • Permeation (Ar and CO2) determination of: • Hostaphan RNK 2600 Cu100/Au20 (ongoing) • Hostaphan RNK 2600 with welding NA62 straw working group meeting; W.V. & D.L.D.